Evidence map›Paper›PMID 42363089›Full record

ArticleBMC ophthalmology2026

Combining structural and microvascular parameters via machine learning for enhanced diagnosis of normal-tension glaucoma among highly myopic eyes: a prospective cross-sectional diagnostic accuracy study.

Chang-Zhu He, Qin Qiu, Heng Lai, Chun-Yan Lai, Yu He, Lin Jing

Abstract read
In one paragraph

Article in BMC ophthalmology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Chang-Zhu HeDepartment of Ophthalmology, Chengdu First People's Hospital/Chengdu Integrated TCM and Western Medicine Hospital, Chengdu, Sichuan Province, 610041, China.
Qin QiuDepartment of Ophthalmology, Chengdu First People's Hospital/Chengdu Integrated TCM and Western Medicine Hospital, Chengdu, Sichuan Province, 610041, China.
Heng LaiDepartment of Ophthalmology, Chengdu First People's Hospital/Chengdu Integrated TCM and Western Medicine Hospital, Chengdu, Sichuan Province, 610041, China.
Chun-Yan LaiDepartment of Ophthalmology, Chengdu First People's Hospital/Chengdu Integrated TCM and Western Medicine Hospital, Chengdu, Sichuan Province, 610041, China.
Yu HeDepartment of Ophthalmology, Chengdu First People's Hospital/Chengdu Integrated TCM and Western Medicine Hospital, Chengdu, Sichuan Province, 610041, China. 17381859326@163.com.ORCID http://orcid.org/0000-0002-9319-737X
Lin JingDepartment of Ophthalmology, Chengdu First People's Hospital/Chengdu Integrated TCM and Western Medicine Hospital, Chengdu, Sichuan Province, 610041, China. 15928676585@163.com.

Funding

Chengdu Science and Technology Bureau Project 2024-YF05-01279-SN
6 · The paper itself

Abstract

purposeThis study aimed to evaluate whether a combination of optical coherence tomography (OCT) and OCT angiography (OCTA) parameters could improve the discrimination between clinically diagnosed normal-tension glaucoma (NTG) and non-glaucomatous high myopia (HM) within a highly myopic population.

methodsIn this prospective cross-sectional diagnostic accuracy study, we consecutively enrolled two groups of participants: patients with high myopia (HM) and those with HM complicated by normal-tension glaucoma (HM-NTG). All clinical and imaging data were collected at a single time point using standardized protocols. Baseline clinical data were collected for all participants. Optic disc structural parameters were acquired using optical coherence tomography (OCT), while optic disc perfusion parameters were obtained via OCT angiography (OCTA). Receiver operating characteristic (ROC) curve analysis was first conducted to evaluate the diagnostic performance of individual parameters. Least absolute shrinkage and selection operator (LASSO) regression was employed for preliminary dimensionality reduction and feature selection, followed by multivariate logistic regression (backward stepwise method) to identify the optimal parameter combination. A diagnostic model was developed based on logistic regression and rigorously validated through bootstrap resampling, calibration assessment, decision curve analysis, and clinical impact curve. A machine learning diagnostic model was constructed using the support vector machine (SVM) algorithm and compared with the conventional regression model. Finally, Shapley additive explanations (SHAP) were applied to interpret the SVM model's decision-making mechanism and elucidate the individualized contribution of each feature to the prediction outcomes.

resultsA total of 87 patients were enrolled, comprising 42 in the HM group and 45 in the HM-NTG group. Overall, OCT parameters demonstrated superior diagnostic clarity compared with OCTA microvascular indices. The inferior macular ganglion cell complex (GCC) exhibited the strongest discriminatory performance, with an area under the receiver operating characteristic curve (AUC) of 0.85. Among OCTA parameters, the inferior optic disc vessel density (VD) achieved the best diagnostic performance (AUC = 0.72). LASSO regression combined with multivariate logistic regression identified three variables for model construction: inferior GCC thickness (odds ratio [OR] = 0.72), temporal-inferior retinal nerve fiber layer (RNFL) thickness (OR = 0.82), and inferior VD (OR = 0.77). The OCT + OCTA combined model achieved an AUC of 0.909 (95% CI: 0.833-0.984). While this did not significantly exceed the OCT-only model (AUC = 0.888, 95% CI: 0.803-0.973; DeLong test, P = 0.164), the addition of OCTA-derived inferior vessel density yielded significant net reclassification improvement (NRI = 0.679, P = 0.003) and integrated discrimination improvement (IDI = 0.067, P = 0.029), indicating enhanced risk stratification. Bootstrap resampling with 500 iterations yielded an AUC of 0.861 (95% CI: 0.773-0.949). The Hosmer-Lemeshow goodness-of-fit test indicated adequate calibration (χ² = 6.64, P = 0.575), with a Brier score of 0.109. Calibration curves demonstrated close adherence to the ideal diagonal across both low-risk and high-risk probability thresholds. Decision curve analysis indicated favorable net benefit. An SVM model constructed using the same three predictors achieved a comparable AUC of 0.908 (95% CI: 0.833-0.982), providing cross-algorithmic validation of the logistic model's robustness. SHAP analysis was applied to elucidate individualized feature contributions to patient-specific predictions, confirming that lower values of inferior GCC thickness exerted the greatest directional influence on HM-NTG classification.

conclusionsWithin highly myopic eyes, the combination of inferior GCC thickness, temporal-inferior RNFL thickness, and inferior VD may help distinguish clinically diagnosed HM-NTG from non-glaucomatous HM. The addition of OCTA microvascular parameters did not significantly increase the AUC but improved patient risk reclassification. This multimodal approach, paired with conventional regression and machine learning, offers a promising adjunctive tool for diagnostic evaluation in highly myopic eyes.

Indexed as

Low Tension GlaucomaMachine LearningMyopia, DegenerativeOptic DiskTomography, Optical CoherenceCross-Sectional StudiesFemaleFluorescein AngiographyHumansIntraocular PressureMaleMiddle AgedProspective StudiesReproducibility of ResultsROC CurveVisual FieldsHigh myopiaMachine learningNormal-tension glaucomaOptical coherence tomographyOptical coherence tomography angiography

Identifiers

PMID42363089
PMCPMC13576206

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.