Evidence map›Paper›PMID 42360978›Full record

ArticleStereotactic and functional neurosurgery2026

A Fully Magnetic Resonance Imaging-Compatible, Nonelectrical System for Near-Real-Time Tremor Monitoring during Magnetic Resonance-Guided Focused Ultrasound.

Adrien Lavalley, Orane Lorton, Paul Constanthin, Vanessa Fleury, Shahan Momjian

Abstract read
In one paragraph

Article in Stereotactic and functional neurosurgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Adrien LavalleyDepartment of Neurosurgery, Geneva University Hospital (HUG), Geneva, Switzerland.
Orane LortonDepartment of Neurosurgery, Geneva University Hospital (HUG), Geneva, Switzerland, orane.lorton@hug.ch.
Paul ConstanthinDepartment of Neurosurgery, Geneva University Hospital (HUG), Geneva, Switzerland.
Vanessa FleuryFaculty of Medicine, University of Geneva, Centre Médical Universitaire, Geneva, Switzerland.
Shahan MomjianDepartment of Neurosurgery, Geneva University Hospital (HUG), Geneva, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionTremor quantification during magnetic resonance-guided focused ultrasound (MRgFUS) for essential tremor remains a clinical challenge. Current methods, such as accelerometry, can still be limited by electromagnetic artifacts in certain cases, magnetic resonance imaging (MRI) incompatibility, and indirect correlation with sonication timing. We aimed to develop a fully MRI-compatible, nonelectrical system capable of continuous, electromagnetically artifact-free tremor monitoring with near-real-time frequency analysis, precisely synchronized with ultrasound delivery. The primary purpose of this tool is to assist with targeting during the verification stage by providing the tremor amplitude in situ.

methodsWe designed a pneumatic device using a standard, easily available endotracheal cuff inflated to a fixed pressure, held by the patient during MRgFUS sonications. Tremor-induced pressure fluctuations were transmitted outside the MRI suite and digitized using a custom Arduino-based system. A software tool was implemented to calculate the tremor amplitude in near-real time.

resultsThe pressure system allowed real-time visualization of the tremor and assessment of the tremor reduction at the verification stage of 10 patients. The mean tremor reduction was 86% immediately after the end of the verification sonication, confirming the correct position of the target. All patients had a lesion at this location except one, in which the target was moved because he experienced sensory side effects.

conclusionWe designed and implemented a near-real-time pressure system for quantification of the tremor amplitude during sonications. The inexpensive and MR-compatible device is easy to implement on patients requiring MRgFUS treatments and avoid the possible loss of information between the temporary tremor reduction and the clinical evaluation.

Indexed as

Essential tremor monitoringMagnetic resonance-guided focused ultrasoundMagnetic resonance imaging-compatible devicePressure sensorReal-time tremor evaluation

Identifiers

PMID42360978
PMCPMC13456661

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.