Evidence map›Paper›PMID 42358912›Full record

ArticleActa stomatologica Croatica2026

Impact of PVM/MA Copolymer on Dentin Bond Durability.

Fusun Ozer, Frances Park, Batu Can Yaman, Zeynep Ozkurt-Kayahan, Francis Mante, Markus B Blatz

Abstract read
In one paragraph

Article in Acta stomatologica Croatica, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Fusun OzerDepartment of Preventive and Restorative Sciences, University of Pennsylvania, School of Dental Medicine, Philadelphia, PA, USA.ORCID https://orcid.org/0000-0003-1213-4957
Frances ParkDepartment of Preventive and Restorative Sciences, University of Pennsylvania, School of Dental Medicine, Philadelphia, PA, USA.ORCID https://orcid.org/0009-0006-1840-6211
Batu Can YamanDepartment of Operative Dentistry, Osmangazi University, Faculty of Dentistry, Eskisehir, Turkey.ORCID https://orcid.org/0000-0003-4295-0760
Zeynep Ozkurt-KayahanDepartment of Prosthodontics, Yeditepe University, Faculty of Dentistry, Istanbul, Turkey.ORCID https://orcid.org/0000-0002-3320-9244
Francis ManteDepartment of Preventive and Restorative Sciences, University of Pennsylvania, School of Dental Medicine, Philadelphia, PA, USA.ORCID https://orcid.org/0000-0001-9656-9784
Markus B BlatzDepartment of Preventive and Restorative Sciences, University of Pennsylvania, School of Dental Medicine, Philadelphia, PA, USA.ORCID https://orcid.org/0000-0001-6341-7047

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: This study investigated the effect of Polymethyl vinyl ether-co-maleic anhydride (PVM/MA) copolymer incorporation and aging with thermocycling on the shear bond strength (SBS) of an etch-and-rinse adhesive (Adper Single Bond Plus-ASB) and two different self-etch adhesive systems (Clearfil SE Bond-CSE and Fluorobond II-FLB) to dentin. Materials and Methods: Adhesive systems were applied to 240 dentin sections randomly selected from the occlusal surfaces of 60 extracted molar teeth. The test groups were as follows (n=20): (G1) Pure Clearfil SE (CSE) Bond; (G2) CSE with copolymer (50 mg/ml PVM/MA); (G3) Pure FL II Bond (FLB); (G4) FLB with copolymer (50 mg/ml PVM/MA); (G5) Pure Adper Single Bond (ASB); and (G6) ASB with copolymer (50 mg/ml PVM/MA). A resin composite (Clearfil Majesty Posterior) was applied to the dentin surfaces and light-cured. Half of the specimens from each group were tested immediately after preparation (IM) and the other half was tested after exposure to 20,000 thermal cycles (TC; 5-55 °C). SBS values were measured at a crosshead speed of 0.5 mm/min. Data were analyzed with ANOVA and Tukey's HSD. Results: The PVM/MA copolymer incorporation improved the performance of CSE in the IM group and ASB in the TC group, however, it showed no influence in the other adhesive groups. The self-etch adhesive CSE with the PVM/MA copolymer showed the highest bond strength to dentin surfaces in the IM group (22.0±1.7 MPa). However, copolymer corporation did not increase bonding performance of Fluor containing bonding agent FLB. Thermocycling of test specimens significantly decreased bond strengths in all test groups except for ASB resin adhesive with PVM/MA copolymer. Conclusion: Incorporating PVM/MA into ethanol-based, hydrophilic all-in-one bonding agents may offer a valuable strategy to improve the long-term stability of adhesive systems.

Indexed as

Adhesivenessbond durabilitydentin adhesionMeSH Terms: Dental EtchingPVM/MA copolymershear bond strengthShear Strengththermocycling

Identifiers

PMID42358912
PMCPMC13292663

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.