ArticleSensors (Basel, Switzerland)2026
Linearity Enhancement in Magnetostrictive Sensors Based on Substructure with Tunable Poisson's Ratio.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Magnetostrictive sensors based on the inverse magnetostrictive effect offer the advantages of wireless passive operation and structural simplicity; however, achieving both high sensitivity and superior linearity remains a persistent challenge. This study presents a magnetostrictive pressure sensor incorporating a tunable Poisson's ratio (TPR) chiral auxetic honeycomb substructure, designed to linearize the stress response of the sensing material. A theoretical model linking substructure design parameters to sensor output linearity was derived and validated through finite element simulations. The fabricated substructure exhibited a stable negative Poisson's ratio (-1.278 to -1.213) within its elastic regime and a highly linear axial-to-transverse strain relationship (x = 1.214y + 0.113). The sensor achieved a calibration linearity of R
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.