ArticleSensors (Basel, Switzerland)2026
Bridging the Bond: High-Sensitivity External Printed Strain Sensors for Condition Monitoring of Adhesive Joints.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
Adhesive joints typically require high safety factors, as their mechanical performance is highly sensitive to environmental and manufacturing variations. Health monitoring can reduce these safety factors by continuously assessing the condition of the joint. While intrinsic and extrinsic sensing approaches exist, they are often based on periodic inspection or manual sensor integration, which limits their suitability for continuous in-service monitoring. This study investigates a novel sensor placement using additively manufactured strain sensors deposited by jet dispensing across the adhesive gap. Tensile lap-shear specimens were fabricated using CFRP (carbon-fiber-reinforced plastic) laminate, an epoxy adhesive, and silver-ink strain sensors placed internally within the joint and externally across the adhesive gap. Mechanical testing revealed that externally printed sensors produced an average resistance change of 65.3% near the failure stress of the adhesive joint, an order of magnitude higher than sensors embedded within the adhesive layer with 6.6% average resistance change. However, the average coefficient of variation increased as well, from 7.6% for internal to 32.6% for external. This sensor response exceeds reported environmentally induced variations in printed sensors and thus represents a promising candidate for condition monitoring. Further work is required to demonstrate actual damage detection capabilities and assess long-term stability under environmental and cyclic loading conditions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.