Evidence map›Paper›PMID 42356679›Full record

ArticleSensors (Basel, Switzerland)2026

Real-Time Kinematic Reconstruction of Human Lower Limbs Using a 3-IMU Wearable Sensor Network, Transformer Model, and Deployable Edge Computing.

Yang Yu, Wei Dong, Hui Dong, Wenda Wang, Yongzhuo Gao, Dongmei Wu, Weiqi Lin

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yang YuState Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China.ORCID 0009-0007-2868-2604
Wei DongState Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China.ORCID 0000-0002-1211-6444
Hui DongState Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China.ORCID 0000-0002-8562-6787
Wenda WangState Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China.ORCID 0009-0004-6062-6803
Yongzhuo GaoState Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China.ORCID 0000-0002-1267-4550
Dongmei WuState Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China.
Weiqi LinState Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China.ORCID 0009-0008-9529-4107

Funding

State Key Laboratory of Robotics and Systems SKLRS202509BState Key Laboratory of Robotics and Systems SKLRS 2025-ZM-02
6 · The paper itself

Abstract

Continuous monitoring of lower-limb kinematics in natural environments is essential for gait analysis and rehabilitation but remains challenging due to the limitations of optical systems and the inaccuracy of sparse inertial sensor methods. To address this, we propose a high-precision, minimalist wearable system utilizing only three inertial measurement units placed on the pelvis and shanks. In the data preprocessing stage, engineering modifications are made based on the traditional gradient descent algorithm to implement adaptive channel adjustment on the acceleration and magnetic data of a single IMU, aiming to alleviate the impact of motion acceleration and external magnetic interference on the temporal feature manifold. Subsequently, a pure Transformer neural network is utilized to capture long-range temporal dependencies, reconstructing full lower-limb kinematics without relying on rigid biomechanical assumptions. The model was optimized and deployed on an STM32N647 microcontroller to achieve real-time edge inference with a low latency of approximately 17 ms. Experimental results demonstrate that the proposed method achieves a mean absolute error of 2.41° for level walking, significantly outperforming traditional constrained Kalman filter approaches. Furthermore, it maintains high tracking robustness during complex nonlinear movements such as squatting and lunging. In conclusion, this edge-computing-enabled framework provides an accurate, comfortable, and real-time solution for unconstrained human motion capture in daily scenarios.

Indexed as

Lower ExtremityWearable Electronic DevicesAlgorithmsBiomechanical PhenomenaGaitHumansMotion CaptureNeural Networks, ComputerWalkingedge computinghuman motion captureinertial measurement unit (IMU)kinematic reconstructionwearable sensors

Identifiers

PMID42356679
PMCPMC13307031

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.