Evidence map›Paper›PMID 42356615›Full record

ArticleSensors (Basel, Switzerland)2026

Improving Signal Quality in Non-Contact Electrocardiography: Novel Strategy for Motion Artifact Reduction.

Antonio Stanešić, Luka Klaić, Dino Cindrić, Mario Cifrek

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Antonio StanešićUniversity of Zagreb Faculty of Electrical Engineering and Computing, 10000 Zagreb, Croatia.ORCID 0009-0003-0880-3895
Luka KlaićUniversity of Zagreb Faculty of Electrical Engineering and Computing, 10000 Zagreb, Croatia.ORCID 0009-0003-9251-5502
Dino CindrićUniversity of Zagreb Faculty of Electrical Engineering and Computing, 10000 Zagreb, Croatia.ORCID 0009-0006-1465-4883
Mario CifrekUniversity of Zagreb Faculty of Electrical Engineering and Computing, 10000 Zagreb, Croatia.ORCID 0000-0002-7554-0824

Funding

Croatian Science Foundation HRZZ-DOK-2021-02-9585Croatian Science Foundation HRZZ-DOK-2025-02-5173Croatian Science Foundation HRZZ-IP-2024-05-2808European Commission IIP_VISTAHealthEuropean Commission PK.1.1.10.0007 (DATACROSS)Ministry of Science and Education of Croatia Kina Veliki
6 · The paper itself

Abstract

Capacitive electrocardiography (cECG) enables non-contact heart rate monitoring through clothing, but motion artifacts remain a critical limitation for practical applications. We present a novel motion artifact removal method using non-contact floating electrodes as noise references combined with multi-reference Normalized Least Mean Squares (NLMS) adaptive filtering. The floating electrodes, positioned without skin contact, couple primarily to ambient 50 Hz mains interference, which becomes amplitude-modulated during motion due to changes in electrode-body capacitance. Six reference signals are derived from this noise electrode: band-pass-filtered signal and its derivative (capturing baseline-type artifacts), envelope and its derivative (capturing amplitude modulation patterns), and envelope asymmetry and its derivative (capturing non-linear electrode response during motion). The NLMS algorithm adaptively combines these references to estimate and remove motion artifacts while preserving QRS morphology through low-pass filtering of the correction signal. A hysteresis-based motion detector with minimum duration constraints enables selective application of artifact removal only during motion periods, leaving rest-period ECG unmodified. We present this as a proof-of-concept validation of a novel reference-electrode architecture for motion artifact suppression in non-contact ECG. The method was validated on 7 subjects across 24 recording sessions using two electrode configurations in two environments with different electromagnetic interference levels. Controlled axial rotation motion was induced at three frequencies using a custom apparatus with IMU-based gamification for protocol adherence. Performance was evaluated using R-peak detection

Indexed as

ElectrocardiographySignal Processing, Computer-AssistedAlgorithmsArtifactsElectrodesHeart RateHumansMotionbiomedical signalsbiopotentialscapacitive electrodescECGECGgamificationmulti-referenced NLMSNLMSnoncontact electrodesPLIQRS

Identifiers

PMID42356615
PMCPMC13306560

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.