ArticleBioengineering (Basel, Switzerland)2026
Biomechanical Behavior of Composite Bone-Osteosynthesis Constructs in Complex Proximal Humerus Fractures: A Synergistic Experimental and Finite Element Approach.
Article in Bioengineering (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
This study evaluates the mechanical behavior of bone-implant assemblies used in treating complex proximal humerus fractures, a clinical challenge due to the anisotropic nature of bone and variability in patient-specific conditions. The aim of this study was to compare the stability and stress distribution of three fixation methods: polyaxial locking plates, monoaxial locking plates, and intramedullary nails. Using 4th-generation composite humerus models, a four-part fracture (Neer IV) was simulated. The assemblies underwent axial compression testing using a universal testing machine, complemented by finite element analysis (FEA) and stereomicroscopy. The results indicate that while both plate types exhibited similar mechanical behavior-with stiffness values around 113-115 N/mm and failure initiated by plastic deformation of the implant-the intramedullary nail configuration demonstrated higher stiffness values under the tested experimental conditions (1084 N/mm), approximately 9.5 times higher than that of the plates. However, the nail assembly failed through brittle fracture of the bone rather than implant deformation. We conclude that while the intramedullary nail configuration demonstrated higher stiffness under the tested experimental conditions, its performance is heavily dependent on bone quality. In contrast, locking plates may provide a more gradual load-transfer behavior by transferring a greater proportion of the mechanical load to the implant, potentially making them more suitable for osteoporotic bone conditions, where reducing excessive stress concentration within the bone tissue may be beneficial.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.