Evidence map›Paper›PMID 42351846›Full record

ArticleBioengineering (Basel, Switzerland)2026

Environment-Driven Synthetic Baseline Analysis and Optimization in Joint Measurement OPM-MEG Arrays.

Wenli Wang, Jianxin Yang, Weinan Xu, Fuzhi Cao, Nan An, Zhenfeng Gao, Min Xiang, Wen Li

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Wenli WangKey Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China.
Jianxin YangKey Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China.
Weinan XuKey Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China.ORCID 0000-0003-2837-2028
Fuzhi CaoKey Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China.ORCID 0000-0002-0510-2757
Nan AnHangzhou Institute of National Extremely-Weak Magnetic Field Infrastructure, 465 Binan Rd., Binjiang District, Hangzhou 310051, China.
Zhenfeng GaoKey Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China.
Min XiangKey Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China.ORCID 0000-0002-0239-3392
Wen LiKey Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China.

Funding

a grant from the Beijing Municipal Science & Technology Commission and Zhongguancun Science Park Administrative Committee Z251100000425001the China Postdoctoral Science Foundation under Grant 2024M754067, 2025M784303the Construction of the National Key Laboratory of Traditional Chinese Medicine Syndromes 2024ZY01035the Fundamental and Interdisciplinary Disciplines Breakthrough Plan of the Ministry of Educa-tion of China JYB2025XDXM606the Key Laboratory of Weak Magnetic Detection Technology, Ministry of Education, the Innova-tion Program for Quantum Science and Technology No.2021ZD0300503the National Natural Science Foundation of China 62401028the Postdoctoral Fellowship Program (Grade B) of the China Postdoctoral Science Foundation GZB20250981
6 · The paper itself

Abstract

Optically pumped magnetometer-based magnetoencephalography (OPM-MEG), with its flexible sensor configuration and wide range of application scenarios, has become a powerful complement to conventional superconducting quantum interference device magnetoencephalography (SQUID-MEG). However, this higher flexibility also means that OPM-MEG sensor arrays are more susceptible to interference from complex and variable background magnetic noise. Previous research has shown that deploying reference sensors around the scalp array for noise cancellation is an effective strategy. Nonetheless, the selection of its key parameter, the spatial distance between the reference and scalp sensors, commonly termed the synthetic baseline, predominantly relies on empirical rules and lacks systematic theoretical optimization. To address this issue, this study thoroughly investigates the fundamental impact of the synthetic baseline on the system's noise suppression performance. Simulation results demonstrate that the optimal baseline length is not a fixed value but varies systematically with environmental noise characteristics and the specific requirements of the source localization task. Building on this analysis, a Baseline Adaptive Reference Optimization (BARO) method is proposed. As an environment-driven strategy, the BARO method automatically determines the optimal baseline configuration by maximizing the output signal-to-noise ratio (SNR). Compared to traditional fixed-baseline configurations, the proposed BARO method significantly enhances the output SNR and effectively reduces the localization error of equivalent current dipoles within the brain across various simulated complex noise scenarios. This work provides a physically interpretable criterion for baseline optimization and offers theoretical support for environment-adaptive configuration of OPM-MEG sensor arrays.

Indexed as

joint measurement sensor arraymagnetoencephalographyOPM-MEGsource localizationsynthetic baseline

Identifiers

PMID42351846
PMCPMC13295311

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.