ArticleJMIR biomedical engineering2026
Effect of a Spinal Orthosis With Leaf Spring and Programmable Local Vibration on Kyphosis Angle and Trunk Muscle Strength in Hyperkyphosis: Development and Feasibility Study.
Article in JMIR biomedical engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: The application of spinal orthoses and local vibration in the treatment of hyperkyphosis is a developing concept. Further research is needed to determine the impact of leaf springs and local vibration techniques on the neuromusculoskeletal system. Objective: This study aimed to evaluate the effect of the simultaneous application of a leaf spring and a programmed local vibration system in a spinal orthosis on thoracic kyphosis angle (TKA) and the function of trunk flexor and extensor muscles. Methods: We used a soft thoracolumbar orthosis as a base for 2 parallel leaf spring bars made from AISI (American Iron and Steel Institute) 1075 steel (45 cm × 2 cm × 2 mm each). We added 4 solenoid actuators (60 g each) housed in 2 units positioned 12 cm apart, generating 20 N vertical force at 8 Hz frequency with 10 mm free displacement. A programmable Arduino microcontroller delivered 10-second vibration bursts followed by 5-minute rest intervals, repeated for 12 cycles per session, applied every other day. One participant with hyperkyphosis (baseline TKA=47.24°) used this device for 4 weeks. Outcomes included TKA (measured by photogrammetry) and trunk muscle function (assessed under isometric, isotonic, and isokinetic conditions). Feasibility outcomes included adherence, wear time, and adverse events. Results: Bench testing confirmed an 8 Hz vibration frequency, a 10 mm free displacement, and an on-body contact pressure of 9.5 N/cm² (95 kPa). In the short-term assessment (N=10), mean acceptability scores were 7.95 (SD 0.83) for appearance and 7.6 (SD 0.07) for comfort, and no skin-related adverse events occurred. In the 4-week single-participant pilot (N=1), adherence was 100% (12/12 sessions completed), mean daily wear time was 1.4 (SD 0.3) hours, and no adverse events were reported. TKA decreased from 47.24° to 45.81° (change: -1.43°), which did not exceed the minimal detectable change (4.62°). Pre-post changes in muscle function outcomes are reported descriptively. Conclusions: A semirigid thoracolumbar orthosis with integrated programmable vibration (8 Hz, 20 N free force) is technically feasible, showing reliable bench performance. Short-term assessment in 10 participants indicated acceptable comfort and appearance with no immediate safety concerns. The 4-week single-participant pilot demonstrated 100% adherence and no adverse events. The observed 1.43° kyphosis reduction was not clinically meaningful (below minimal detectable change). Larger controlled studies are needed to determine whether this device improves muscle function or spinal alignment.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.