Latent density discrepancies in commercial lung-equivalent inserts and their clinical dosimetric impact.

Minoru Nakao, Shuichi Ozawa, Hideharu Miura, Masahiro Hayata, Kosaku Habara, Masahiro Kenjo

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Minoru NakaoHiroshima High-Precision Radiotherapy Cancer Center, Hiroshima, Japan.ORCID https://orcid.org/0000-0001-5473-4956
Shuichi OzawaHiroshima High-Precision Radiotherapy Cancer Center, Hiroshima, Japan.
Hideharu MiuraHiroshima High-Precision Radiotherapy Cancer Center, Hiroshima, Japan.
Masahiro HayataHiroshima High-Precision Radiotherapy Cancer Center, Hiroshima, Japan.
Kosaku HabaraHiroshima High-Precision Radiotherapy Cancer Center, Hiroshima, Japan.
Masahiro KenjoHiroshima High-Precision Radiotherapy Cancer Center, Hiroshima, Japan.

Funding

Japan Society for the Promotion of Science 23K14869Japan Society for the Promotion of Science 24K15811Japan Society for the Promotion of Science 26K10682
6 · The paper itself

Abstract

backgroundAccurate heterogeneity correction in high-precision radiotherapy relies on precise computed tomography (CT) number-to-density conversion via the Hounsfield unit look-up table (HLUT). While physical properties of tissue-equivalent materials are generally assumed consistent with manufacturer specifications, an independent audit identified clinically significant density discrepancies in commercially available lung-equivalent phantom inserts. PURPOSE: This study evaluates the physical properties of nonconforming lung inserts through mass measurements and stoichiometric analysis, and assesses the clinical dosimetric impact of the associated density discrepancies.

methodsFive lung-inhale inserts manufactured in 2010, 2015, and 2024 (10A, 10B, 15A, 15B, and 24A) were analyzed. Mass and physical dimensions were measured in triplicate using a precision balance (1 mg resolution) and vernier calipers. Stoichiometric analysis was conducted using reference materials to evaluate the tissue-equivalence of the inserts and quantify deviations from the theoretical baseline. A nonconforming table and a conforming reference table (RT) were established, derived from inserts 10A and 24A, respectively. For clinical impact assessment, volumetric modulated arc therapy (VMAT) plans for three clinical cases involving centrally located lung tumors (utilizing both inspiration breath-hold (IBH) and free-breathing) were optimized for stereotactic body radiotherapy (SBRT) and recalculated with the RT using the Acuros XB algorithm. Differences in gross tumor volume (GTV) mean dose and planning target volume (PTV) D95% were evaluated to quantify the dosimetric consequences.

resultsThe 2010 inserts (10A and 10B) exhibited a 17.1% mass reduction and lower CT numbers compared to the reference 24A insert. Dimensional variations were negligible (≤ 0.2 mm) across all samples. Clinical recalculation revealed maximum dose reductions of 2.1% for the GTV mean dose and 3.0% for the PTV D95% in the worst-case scenario. These errors exceed the 2% clinical tolerance, propagated by HLUT interpolation across the low-density range.

conclusionsSubstantial inter-lot density variations in commercial calibration phantoms can lead to dosimetric errors that exceed established clinical limits, particularly for centrally located tumors treated with IBH. Medical physicists must not implicitly rely on nominal manufacturer values; independent audits and initial mass screening at acceptance are highly recommended for maintaining dose calculation accuracy.

Indexed as

Lung NeoplasmsPhantoms, ImagingRadiotherapy Planning, Computer-AssistedTomography, X-Ray ComputedHumansImage Processing, Computer-AssistedOrgans at RiskRadiotherapy DosageRadiotherapy, Intensity-ModulatedCT number calibrationquality assurancetreatment planning

Identifiers

PMID42348060
PMCPMC13296812

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.