Evidence map›Paper›PMID 42347486›Full record

ArticleMuscles (Basel, Switzerland)2026

Intra-Rater, Inter-Rater, and Test-Retest Reliability of a Laser- and Inclinometer-Based Hip Joint Position Sense Test in Healthy Adults: A Two-Phase Study with Preliminary Reference Values.

Joévin Burnel, Benoit Vallee, Benoit Pairot de Fontenay, Joachim Van Cant

Abstract read
In one paragraph

Article in Muscles (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Joévin BurnelResearch Unit in Rehabilitation Sciences, Faculty of Human Movement Sciences, Université Libre de Bruxelles, Route de Lennik 808, 1070 Bruxelles, Belgium.ORCID 0009-0007-7619-9385
Benoit ValleeInstitut de Formation en Masso-Kinésithérapie de L'Est-Francilien (IFMKEF), 77124 Chauconin-Neufmontiers, France.
Benoit Pairot de FontenayRamsay Santé, Clinique de la Sauvegarde, 69009 Lyon, France.ORCID 0000-0002-5327-6786
Joachim Van CantResearch Unit in Rehabilitation Sciences, Faculty of Human Movement Sciences, Université Libre de Bruxelles, Route de Lennik 808, 1070 Bruxelles, Belgium.ORCID 0000-0002-8255-1150

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Hip joint position sense (JPS), a key component of neuromuscular function arising from muscle spindle and periarticular mechanoreceptor input, remains underexplored, with no standardized and reliable clinical protocol available to assess hip proprioception. This study evaluated the intra- and inter-rater reliability of a laser- and inclinometer-based active hip JPS protocol and established preliminary references in healthy adults. A two-phase reliability study was conducted in accordance with GRRAS and COSMIN guidelines: 17 participants for reliability analyses and 57 for preliminary references. Six movement directions were assessed (flexion, extension, abduction, adduction, medial and lateral rotations). Reliability was quantified using intraclass correlation coefficients with their 95% confidence intervals, using two-way random-effects models with absolute agreement (ICC(3,1) for intra-rater and ICC(2,1) for inter-rater analyses), interpreted as poor (<0.50), moderate (0.50-0.70), or good (≥0.70). Absolute measurement error was reported as standard error of measurement (SEM%) and 95% minimal detectable change (MDC95%), normalized to target amplitudes to allow direct cross-direction comparison. Intra-rater reliability ranged from poor to moderate, with experienced raters reaching ICC = 0.64 (95% CI [0.39; 0.80]) for medial rotation. Inter-rater reliability improved across sessions, peaking for medial rotation (ICC = 0.78; 95% CI [0.50; 0.91]). Rotational movements yielded the lowest SEM% (3-6%), indicating high measurement precision despite trial-to-trial variability (MDC% 9-31%). Normative errors were largest in flexion (21.4 cm) and smallest in rotations (≈2.2-2.3°). Despite overall low-to-moderate reliability, the protocol achieved clinically acceptable measurement precision (SEM% < 10%) for rotational tasks, whereas the laser-based sagittal and frontal-plane components remained exploratory. The protocol provides preliminary reference values for hip JPS in healthy adults and requires further validation before clinical use.

Indexed as

clinimetricship proprioceptionjoint position sensemuscle functionneuromuscular controlreliability

Identifiers

PMID42347486
PMCPMC13304680

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.