ArticleToxics2026
Validation of the Electrophilic Allergen Screening Assay for Detection of Key Event 1 of the Skin Sensitization Adverse Outcome Pathway.
Article in Toxics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
15 authors.
Funding
Abstract
The electrophilic allergen screening assay (EASA) uses small-molecule probes as surrogates for skin proteins to measure hapten protein carrier complex formation, Key Event (KE) 1 in the adverse outcome pathway for skin sensitization. Although multiple assays are accepted for this purpose, the EASA has higher throughput and needs less specialized equipment than other commonly used KE1 assays. This validation study assessed transferability of the EASA to naïve laboratories and within- and between-laboratory reproducibility. The predictive capacity of the assay in relation to reference data both from the murine local lymph node assay (LLNA) and, where available, human predictive patch tests, was estimated. The validation study was conducted using performance standards developed for methods that are under evaluation for inclusion in relevant test guidelines. The within- and between-laboratory reproducibility were cumulatively 96% and 85%, respectively. These scores exceeded the performance standard thresholds of 80%. Compared to reference LLNA data, the cumulative EASA results from the four laboratories had an overall sensitivity of 87%, specificity of 76%, and accuracy of 83%. The consensus results among the four laboratories had an overall sensitivity of 85%, specificity of 80%, and accuracy of 83%. For human reference data, the cumulative EASA results had an overall sensitivity of 81%, specificity of 76%, and accuracy of 70%. The EASA predicted sensitizers very well, although it had a slightly higher rate of misclassifying some negative test chemicals as positive with a specificity below the performance standards criterion of 80%. Our findings support further exploring use of the EASA in defined approaches to identify potential skin sensitizers.