Evidence map›Paper›PMID 42346680›Full record

ArticleJournal of functional biomaterials2026

Influence of Printing Parameters and Nozzle Diameter on the Effective Microarchitecture and Compressive Modulus of Gyroid PCL Scaffolds.

José González, Mario E Flores, Luis Medina Uzcátegui, Gabriela Martínez

Abstract read
In one paragraph

Article in Journal of functional biomaterials, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

José GonzálezEscuela de Ingeniería Civil Mecánica, Facultad de Ciencias de la Ingeniería, Universidad Austral de Chile, Valdivia 5090000, Chile.
Mario E FloresInstituto de Ciencias Químicas, Facultad de Ciencias, Universidad Austral de Chile, Valdivia 5090000, Chile.ORCID 0000-0003-4570-1487
Luis Medina UzcáteguiInstituto de Ingeniería Mecánica, Facultad de Ciencias de la Ingeniería, Universidad Austral de Chile, Valdivia 5090000, Chile.ORCID 0000-0001-9681-0590
Gabriela MartínezInstituto de Ingeniería Mecánica, Facultad de Ciencias de la Ingeniería, Universidad Austral de Chile, Valdivia 5090000, Chile.ORCID 0000-0003-0515-9400

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Three-dimensional scaffolds based on triply periodic minimal surfaces (TPMSs) have attracted growing interest in bone tissue engineering because of their high interconnectivity and ability to combine high porosity with mechanical integrity. However, in fused deposition modeling (FDM), printed architecture may systematically deviate from the nominal design, thereby affecting structural fidelity and mechanical performance. This study investigated the influence of FDM processing parameters and nozzle diameter on the effective microarchitecture and compressive elastic modulus of polycaprolactone (PCL) gyroid scaffolds. First, a Taguchi L18 design was used to evaluate the effects of extrusion temperature, printing speed, and flow rate on pore size for two nozzle diameters (0.4 and 0.3 mm). In a second experimental stage, prismatic specimens fabricated at three nominal porosity levels were compression-tested to determine the elastic modulus (E), and measured porosity (ϕ) was quantified by densimetric measurements. A systematic mismatch was observed between the nominal design and the printed scaffold architecture, with both pore size and measured porosity consistently lower than their intended values. The dominant process parameter associated with pore-size variability was nozzle-specific: extrusion temperature contributed most for the 0.4 mm nozzle, whereas printing speed contributed most for the 0.3 mm nozzle. In compression, E decreased with increasing measured porosity, and statistical analysis showed that the E-ϕ relationship was nozzle-dependent. Overall, these findings support a process-structure-property interpretation based on the effective printed microarchitecture rather than on nominal design parameters alone. The experimental stiffness ranges obtained here also provide an exploratory mechanical contextualization relative to reported trabecular bone domains, without implying site-specific scaffold selection.

Indexed as

compressive elastic modulusfused deposition modelinggyroid scaffoldspolycaprolactone (PCL)porosityprocess–structure–property relationship

Identifiers

PMID42346680
PMCPMC13302465

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.