Evaluation of the Effects of Implants with Different Geometries on the Inferior Alveolar Nerve Under Occlusal Stresses.
Article in Journal of functional biomaterials, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
Abstract
Dental implant placement in the posterior mandible can be challenging due to the presence of the inferior alveolar nerve (IAN). Biomechanical factors related to implant design and loading may also influence nerve compression. This study aimed to investigate the influence of implant geometry, diameter, length, and implant-canal distance on IAN pressure. Dental implants with two geometries (tapered and cylindrical), two lengths (8 and 12 mm), and two diameters (3.3 and 4.1 mm) were virtually positioned at three implant-canal distances (0.5, 1.0, and 1.5 mm). A total of 24 finite element models were generated. Functional occlusal loading was simulated using a 300 N vertical force and a 100 N oblique force applied at a 45° angle. The resulting IAN pressure values were determined. The implant diameter affected IAN pressure, with 3.3 mm implants yielding higher values than 4.1 mm implants. Longer implants exhibited lower pressure values than shorter implants. Cylindrical implants generated higher pressure than tapered implants. Increasing the implant-canal distance from 0.5 to 1.5 mm reduced nerve pressure. Vertical loading yielded higher pressure values than oblique loading. The implant-canal distance was the primary factor influencing IAN pressure. Implant diameter and geometry had secondary effects, whereas implant length had a limited influence. These findings highlight the importance of implant planning and design selection to reduce load transfer to the IAN.