ArticleAspects of molecular medicine2026
Development of an isothermal point of care method for detection of human papilloma virus (HPV).
Article in Aspects of molecular medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Current commercial methods of detection of high-risk human papilloma virus (hrHPV) rely mostly on the polymerase chain reaction (PCR) that use either 14 specific primer pairs or a single consensus primer pair (e.g., GP5+/GP6+). However, PCR requires the use of a thermal cycler (PCR machine) and electricity and therefore is not suitable for a low-cost Point of Care Test (PoCT). Moreover, PCR primers are often not suitable for isothermal amplification since at lower temperature they may anneal non-specifically leading to background amplification. We have developed an isothermal point of care method for the rapid detection of hrHPV that works at a constant temperature (<42°C) using recombinase polymerase amplification (RPA). A novel consensus primer pair was designed able to amplify all 14 hrHPV types. To enable the detection of the amplified double-stranded RPA products, one primer was labelled with a 5'-phosphate, and the other primer was labelled at the 5'-end with 6-carboxyfluorescein (FAM). Then, the double-stranded labelled RPA product was digested with Lambda exonuclease, which preferentially digests 5'-phosphorylated DNA ends whereas the 5'-FAM ends are protected, generating single-stranded 5'-FAM-labelled RPA products. These products can be detected by paper-based lateral flow assays (LFA) using biotinylated detection probes that detect all 14 hrHPV types at the same time (universal consensus detection probe). Lateral flow assay conditions were developed that allow these probes to detect all 14 hrHPV types. Using this novel isothermal rapid hrHPV detection method, amplification of all 14 hrHPV types at constant temperature (currently set at 37°C) within short time (<1h) was achieved.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.