Evidence map›Paper›PMID 42344422›Full record

ArticleAspects of molecular medicine2026

Development of an isothermal point of care method for detection of human papilloma virus (HPV).

Jean-Marc Zingg, Pratibha Joshi, Mercedes Lozano-Garcia, Erin Kobetz, Sapna Deo, Sylvia Daunert

Abstract read
In one paragraph

Article in Aspects of molecular medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jean-Marc ZinggDepartment of Biochemistry and Molecular Biology, Miller School of Medicine, University of Miami, Miami, FL, 33136-6129, USA.ORCID 0000-0001-8345-2616
Pratibha JoshiDepartment of Biochemistry and Molecular Biology, Miller School of Medicine, University of Miami, Miami, FL, 33136-6129, USA.
Mercedes Lozano-GarciaDepartment of Biochemistry and Molecular Biology, Miller School of Medicine, University of Miami, Miami, FL, 33136-6129, USA.ORCID 0000-0002-2972-5377
Erin KobetzDr. John T. Macdonald Foundation Biomedical Nanotechnology Institute, University of Miami, Miami, FL, 33146-2101, USA.
Sapna DeoDepartment of Biochemistry and Molecular Biology, Miller School of Medicine, University of Miami, Miami, FL, 33136-6129, USA.ORCID 0000-0003-4760-5528
Sylvia DaunertDepartment of Biochemistry and Molecular Biology, Miller School of Medicine, University of Miami, Miami, FL, 33136-6129, USA.

Funding

Sensitive Detection of Viral Persistency Using Bioluminescent Stem-Loop ProbesR01GM114321 · NIGMS · UNIVERSITY OF MIAMI SCHOOL OF MEDICINE · PI DEO, SAPNA K · 2015 to 2019
$1.5M
Portable, Rapid, Multiplexed Flow strip Test for BacteriaR01GM127706 · NIGMS · UNIVERSITY OF MIAMI SCHOOL OF MEDICINE · PI DAUNERT, SYLVIA, DEO, SAPNA K · 2018 to 2021
$1.2M
NIGMS NIH HHS R01 GM114321NIGMS NIH HHS R01 GM127706
6 · The paper itself

Abstract

Current commercial methods of detection of high-risk human papilloma virus (hrHPV) rely mostly on the polymerase chain reaction (PCR) that use either 14 specific primer pairs or a single consensus primer pair (e.g., GP5+/GP6+). However, PCR requires the use of a thermal cycler (PCR machine) and electricity and therefore is not suitable for a low-cost Point of Care Test (PoCT). Moreover, PCR primers are often not suitable for isothermal amplification since at lower temperature they may anneal non-specifically leading to background amplification. We have developed an isothermal point of care method for the rapid detection of hrHPV that works at a constant temperature (<42°C) using recombinase polymerase amplification (RPA). A novel consensus primer pair was designed able to amplify all 14 hrHPV types. To enable the detection of the amplified double-stranded RPA products, one primer was labelled with a 5'-phosphate, and the other primer was labelled at the 5'-end with 6-carboxyfluorescein (FAM). Then, the double-stranded labelled RPA product was digested with Lambda exonuclease, which preferentially digests 5'-phosphorylated DNA ends whereas the 5'-FAM ends are protected, generating single-stranded 5'-FAM-labelled RPA products. These products can be detected by paper-based lateral flow assays (LFA) using biotinylated detection probes that detect all 14 hrHPV types at the same time (universal consensus detection probe). Lateral flow assay conditions were developed that allow these probes to detect all 14 hrHPV types. Using this novel isothermal rapid hrHPV detection method, amplification of all 14 hrHPV types at constant temperature (currently set at 37°C) within short time (<1h) was achieved.

Indexed as

Cervical cancerHuman papilloma virusIsothermal amplificationLateral flow assayPoint of care test (PoCT)Recombinase polymerase amplification

Identifiers

PMID42344422
PMCPMC13290283

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.