Evidence map›Paper›PMID 42341125›Full record

ArticleScience advances2026

Coordinated hand movement sensation revealed through an implanted magnetic prosthetic kinesthetic interface.

Federico Masiero, Mattia Gentile, Marta Gherardini, Eliana La Frazia, Charles H Moore, B Kilic, Valerio Ianniciello, Roberta Reho, Tommaso Mori, Flavia Paggetti and 4 more

Abstract read
In one paragraph

Article in Science advances, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Federico MasieroThe BioRobotics Institute Scuola Superiore Sant'Anna, Pisa 56127, Italy.ORCID 0000-0003-4271-109X
Mattia GentileThe BioRobotics Institute Scuola Superiore Sant'Anna, Pisa 56127, Italy.ORCID 0009-0006-8853-5828
Marta GherardiniThe BioRobotics Institute Scuola Superiore Sant'Anna, Pisa 56127, Italy.ORCID 0000-0002-2156-5516
Eliana La FraziaThe BioRobotics Institute Scuola Superiore Sant'Anna, Pisa 56127, Italy.ORCID 0009-0008-8259-0871
Charles H MooreLaboratory for Bionic Integration, Department of Biomedical Engineering, Cleveland Clinic Research, 9500 Euclid Avenue, ND20, Cleveland, OH 44195, USA.ORCID 0009-0003-0631-8597
B KilicLaboratory for Bionic Integration, Department of Biomedical Engineering, Cleveland Clinic Research, 9500 Euclid Avenue, ND20, Cleveland, OH 44195, USA.ORCID 0000-0002-4096-8417
Valerio IannicielloThe BioRobotics Institute Scuola Superiore Sant'Anna, Pisa 56127, Italy.ORCID 0000-0002-2756-5162
Roberta RehoThe BioRobotics Institute Scuola Superiore Sant'Anna, Pisa 56127, Italy.ORCID 0009-0006-0070-9927
Tommaso MoriThe BioRobotics Institute Scuola Superiore Sant'Anna, Pisa 56127, Italy.ORCID 0009-0004-4952-3512
Flavia PaggettiThe BioRobotics Institute Scuola Superiore Sant'Anna, Pisa 56127, Italy.
Lorenzo AndreaniOrthopaedics and Traumatology Unit, University Hospital of Pisa, Pisa 56124, Italy.ORCID 0000-0002-8268-6987
Simon A WhittonLaboratory for Bionic Integration, Department of Biomedical Engineering, Cleveland Clinic Research, 9500 Euclid Avenue, ND20, Cleveland, OH 44195, USA.ORCID 0000-0001-9003-7330
Paul D MarascoLaboratory for Bionic Integration, Department of Biomedical Engineering, Cleveland Clinic Research, 9500 Euclid Avenue, ND20, Cleveland, OH 44195, USA.ORCID 0000-0002-1689-7161
Christian CiprianiThe BioRobotics Institute Scuola Superiore Sant'Anna, Pisa 56127, Italy.ORCID 0000-0003-2108-0700

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Muscle contractions to control prosthetic hands do not feel like those to control natural hands because amputation decouples movement sense (kinesthesia) from movement execution. The myokinetic kinesthetic interface (MKkI) uses remote vibration of permanent magnets implanted in amputated forearm muscles to restore kinesthesia. A participant reported coordinated finger movements of hand closing and opening, constrained within physiological bounds, with stereotypical conformations and dynamics. Aggregated unstructured explorations and systematic psychophysics exposed unreported perceptual sensitivity at vibration frequencies that trigger kinesthetic sensations. Complex coordinated grip sensations elicited from single forearm muscles reveal that kinesthetic brain representations are likely rooted in perception of synergistic movement production. By leveraging the natural synergistic features of kinesthesia, the MKkI will help link perception and action to functionally elevate emerging intuitive bidirectional human-machine interfaces.

Indexed as

HandKinesthesisProstheses and ImplantsSensationHumansMovement

Identifiers

PMID42341125
PMCPMC13292950

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked