Article3D printing in medicine2026
Application-matched point-of-care 3D printing of functionalized polyetheretherketone (PEEK) composites for patient-specific craniomaxillofacial implants.
Article in 3D printing in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundNative polyetheretherketone (PEEK) exhibits limitations in mechanical strength, radiographic visibility, and bioactivity for craniomaxillofacial (CMF) applications. This proof-of-concept study establishes the feasibility of point-of-care (POC) manufacturing for three functionalized PEEK composites for patient-specific CMF implants using a high-temperature material extrusion (MEX) system, with application-specific material selection to overcome these limitations.
methodsCarbon fiber-reinforced PEEK (CFR-PEEK), barium sulfate-filled PEEK (BaSO₄-PEEK), and biphasic calcium phosphate-filled PEEK (BCP-PEEK) were fabricated into patient-specific mandibular reconstruction plates, orbital floor implants, and chin augmentation implants, respectively. Manufacturing success rates, dimensional accuracy via root mean square (RMS) deviation analysis, post-sterilization dimensional stability, and layer adhesion quality were evaluated.
resultsFabrication success rates of 100% (CFR-PEEK), 100% (BaSO₄-PEEK), and 85.7% (BCP-PEEK) were achieved. Dimensional accuracy analysis revealed RMS deviations of 0.16-0.29 mm between 3D-printed implants and original designs, within clinically acceptable ranges. Post-sterilization dimensional changes were minimal (RMS 0.05-0.07 mm). Complete layer adhesion was demonstrated across all materials, with no delamination or cracking observed.
conclusionThese findings establish the manufacturing viability of POC fabrication of application-matched PEEK composites for patient-specific CMF implants, enhancing mechanical, radiographic, and bioactive properties whilst maintaining geometric customization.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.