Evidence map›Paper›PMID 42340482›Full record

ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2026

Development of intraoperative fluoroscopic protocols to avoid rotational malalignment during nailing of femoral fractures: a step-by-step guideline using the lesser trochanter profile or true lateral view.

Daniel J Vermue, Pim J Bongers, Kaj Ten Duis, Job N Doornberg, Ruurd L Jaarsma, Mostafa El Moumni, Nils Jan Bleeker, Raul G Plomp, Frank F A IJpma, 3D Surgery Consortium.

Abstract read
In one paragraph

Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Daniel J VermueDepartment of Trauma Surgery, University Medical Center Groningen, Groningen, The Netherlands. d.j.vermue@umcg.nl.
Pim J BongersDepartment of Trauma Surgery, University Medical Center Groningen, Groningen, The Netherlands.
Kaj Ten DuisDepartment of Trauma Surgery, University Medical Center Groningen, Groningen, The Netherlands.
Job N DoornbergDepartment of Trauma Surgery, University Medical Center Groningen, Groningen, The Netherlands.
Ruurd L JaarsmaOrthopaedic Trauma Surgery, Flinders Medical Centre, Bedford Park, Australia.
Mostafa El MoumniDepartment of Trauma Surgery, University Medical Center Groningen, Groningen, The Netherlands.
Nils Jan BleekerDepartment of Orthopaedic Surgery, Amsterdam University Medical Centers, Amsterdam, The Netherlands.
Raul G PlompDepartment of Trauma Surgery, University Medical Center Groningen, Groningen, The Netherlands.
Frank F A IJpmaDepartment of Trauma Surgery, University Medical Center Groningen, Groningen, The Netherlands.
3D Surgery Consortium.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeRotational malalignment (≥ 15°) occurs in up to 35% of femoral fractures after intramedullary nailing, and standardized fluoroscopy protocols to prevent malrotation are lacking. We developed and evaluated two easy-to-use intraoperative fluoroscopy techniques to reduce malrotation.

methodsA human specimen study was performed to compare two standardized fluoroscopy protocols-the lesser trochanter profile and the true lateral view-with current clinical practice. A mid-shaft femoral fracture was created in a full-body cadaver, and an unlocked intramedullary nail was inserted. Random degrees of rotational malalignment were applied using a goniometer and reference wires at the fracture site. Ten physicians (consultants and residents) first estimated malrotation and then performed 150 rotational corrections: 50 according to (unstandardized) clinical practice, 50 using the lesser trochanter profile, and 50 using the true lateral view. The primary outcome was rotational malalignment, measured using reference wires at the fracture site.

resultsClinicians' visual estimation deviated 15.5° [IQR 18.5-12.0] from actual malrotation. Corrections using unstandardized methods resulted in 12.5° [IQR 18.2-6.1] of malrotation. In contrast, the lesser trochanter and true lateral protocols reduced malrotation to 3.9° [6.8-2.1] and 3.6° [8.6-1.4], respectively. Both were significantly more accurate than current practice (p = 0.009 and p = 0.017). Surgeons favoured the lesser trochanter profile for its efficiency, ease-to-use, and minimal need for C-arm repositioning.

conclusionThis study introduces two step-by-step standardized fluoroscopy protocols to prevent rotational malalignment in femoral nailing. Both outperform traditional, unstandardized correction methods, with the lesser trochanter profile offering a more practical and time-efficient option for intraoperative use.

Indexed as

Bone MalalignmentFemoral FracturesFemurFracture Fixation, IntramedullaryBone NailsCadaverFluoroscopyHumansPractice Guidelines as TopicRotationFemurFluoroscopyFracturesLesser trochanterMalrotationTrue lateral technique

Identifiers

PMID42340482
PMCPMC13294287

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.