Evidence map›Paper›PMID 42339060›Full record

ArticleJournal of vascular surgery cases and innovative techniques2026

Aortic dissection false lumen treatment with novel shape memory polymer devices.

Dai Yamanouchi, Yusuke Sakurai, Masaru Nemoto, Sohei Matsuura, Ryohei Maeno

Abstract read
In one paragraph

Article in Journal of vascular surgery cases and innovative techniques, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Dai YamanouchiDivision of Vascular Surgery, Department of Surgery, University of Wisconsin, Madison, WI.
Yusuke SakuraiDepartment of Vascular Surgery, Fujita Health University, Toyoake, Aichi, Japan.
Masaru NemotoDepartment of Vascular Surgery, Fujita Health University, Toyoake, Aichi, Japan.
Sohei MatsuuraDepartment of Vascular Surgery, Fujita Health University, Toyoake, Aichi, Japan.
Ryohei MaenoDepartment of Vascular Surgery, Fujita Health University, Toyoake, Aichi, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this case series, innovative shape memory polymer (SMP) devices were used to treat the aortic dissection false lumen (FL) of five patients. The open-cell, porous structure of expanded SMP contributes to its radiolucency, low radial force, and conformability. The devices were designed to address the unique needs of treating the FL: sufficiently large volume, detachable and stable to minimize migration risk, segmented for flexibility, and with a range of dimensions. All five cases were technically successful. A decrease in total aortic diameter, true lumen restoration, and FL reduction were observed through 6- to 12-month follow-up. The mean changes in maximum aorta diameter from preoperative measurements were -5.8 ± 6.9 mm (30 days, n = 5), -12.0 ± 9.4 mm (6 months, n = 4), and -9.3 ± 0.8 mm (12 months, n = 2). No SMP device/procedure-related complications occurred.

Indexed as

AneurysmAortic dissectionFalse lumen embolizationShape memory polymerThoracic stent graft

Identifiers

PMID42339060
PMCPMC13285698

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.