Evidence map›Paper›PMID 42337534›Full record

ArticleBMC oral health2026

Wear resistance and fracture strength of BioFlx, zirconia and stainless steel crowns for primary molars after thermomechanical aging: an in vitro comparative study.

Alp Abidin Ateşçi, Dilek Özge Yılmaz, Berk Gergit, Münevver Çoruh Kılıç, Hüseyin Şimşek

Abstract readComparative Study
In one paragraph

Article in BMC oral health, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Alp Abidin AteşçiDepartment of Pediatric Dentistry, School of Dentistry, Istanbul Beykent University, Büyükçekmece, Istanbul, Türkiye. alpabidinatesci91@gmail.com.
Dilek Özge YılmazDepartment of Pediatric Dentistry, School of Dentistry, Istanbul Beykent University, Büyükçekmece, Istanbul, Türkiye.
Berk GergitDepartment of Pediatric Dentistry, School of Dentistry, Atatürk University, Erzurum, Türkiye.
Münevver Çoruh KılıçDepartment of Pediatric Dentistry, School of Dentistry, Biruni University, Istanbul, Türkiye.
Hüseyin ŞimşekDepartment of Pediatric Dentistry, School of Dentistry, Ordu University, Ordu, Türkiye.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFull-coverage restorations are often required for primary molars with extensive carious destruction. Stainless steel crowns remain the long-standing reference, while prefabricated zirconia and polymer-based crowns have become tooth-colored alternatives. Direct comparisons under a single thermomechanical protocol, with separate wear and fracture cohorts, remain limited. This in vitro study quantified post-aging occlusal wear and compressive fracture load in four prefabricated crown systems for mandibular second primary molars.

methodsEighty crowns were tested, with 10 specimens per material for each outcome: two prefabricated zirconia crowns, one polymer-based crown, and one stainless steel crown. Identical resin dies were 3D-printed and all crowns were luted with glass-ionomer cement. All specimens underwent 10,000 thermal cycles between 5 °C and 55 °C. The wear cohort underwent 150,000 chewing cycles at 50 N and 1.2 Hz, and wear was scored on a 0-3 scale by two blinded examiners. The fracture cohort was loaded to failure. Wear scores were compared using Kruskal-Wallis and Dunn-Bonferroni tests; fracture loads were analyzed using one-way ANOVA and Tukey HSD.

resultsMean wear scores were 1.1 ± 0.3 for NuSmile, 1.2 ± 0.4 for ProfZr, 1.7 ± 0.4 for SSC, and 2.2 ± 0.4 for BioFlx. The zirconia groups did not differ significantly (p = 0.68), whereas both showed lower wear scores than SSC (p = 0.04) and BioFlx (p = 0.01). SSC also showed lower wear scores than BioFlx (p = 0.03). Mean fracture loads were 3148.4 ± 643.4 N for BioFlx, 2703.4 ± 243.1 N for SSC, 1076.1 ± 186.9 N for NuSmile, and 565.5 ± 159.6 N for ProfZr (p < 0.001). BioFlx and SSC did not differ significantly (p = 0.093), while both exceeded the zirconia groups (p < 0.001). NuSmile exceeded ProfZr (p = 0.043).

conclusionsUnder this in vitro model, zirconia crowns showed the lowest wear scores, whereas BioFlx and SSC showed the highest fracture loads. Each material demonstrated a distinct mechanical profile. Laboratory rankings alone should not guide clinical recommendations; long-term clinical studies are needed.

Indexed as

CrownsDental Restoration WearStainless SteelZirconiumDental Restoration FailureDental Stress AnalysisHumansIn Vitro TechniquesMaterials TestingMolarTooth, DeciduousStainless SteelZirconiumzirconium oxideBioFlxFracture resistanceOcclusal wearPediatric crownPrimary molarStainless steel crownThermomechanical agingZirconia crown

Identifiers

PMID42337534
PMCPMC13548474

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.