Evidence map›Paper›PMID 42332955›Full record

ArticleCancer medicine2026

Marginal Contrast Saturation-Based Intraoperative Scoring System Predicts Objective Response to DEB-TACE: Development and Validation of a CBCT-Derived Real-Time Score.

Zhongsong Gao, Bo Li, Bo Feng, Cheng Sun, Ying Zang, Xin Zhang, Yongmei Wang, Qi Xin, Kefeng Jia, Rong Lyu

Abstract readValidation Study
In one paragraph

Article in Cancer medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Zhongsong GaoDepartment of Interventional Radiology, Central Hospital, Tianjin University/Tianjin Third Central Hospital, Tianjin, China.
Bo LiDepartment of Interventional Radiology, Central Hospital, Tianjin University/Tianjin Third Central Hospital, Tianjin, China.
Bo FengOutpatient Nursing Department, Central Hospital, Tianjin University/Tianjin Third Central Hospital, Tianjin, China.
Cheng SunDepartment of Interventional Radiology, Central Hospital, Tianjin University/Tianjin Third Central Hospital, Tianjin, China.
Ying ZangOutpatient Nursing Department, Central Hospital, Tianjin University/Tianjin Third Central Hospital, Tianjin, China.
Xin ZhangDepartment of Interventional Radiology, Central Hospital, Tianjin University/Tianjin Third Central Hospital, Tianjin, China.
Yongmei WangOutpatient Nursing Department, Central Hospital, Tianjin University/Tianjin Third Central Hospital, Tianjin, China.
Qi XinDepartment of Pathology, Central Hospital, Tianjin University/Tianjin Third Central Hospital, Tianjin, China.ORCID https://orcid.org/0000-0003-3690-598X
Kefeng JiaDepartment of Interventional Radiology, Central Hospital, Tianjin University/Tianjin Third Central Hospital, Tianjin, China.ORCID https://orcid.org/0000-0003-2444-3626
Rong LyuDepartment of Medical Imaging, Central Hospital, Tianjin University/Tianjin Third Central Hospital, Tianjin, China.

Funding

Beijing Medical Award Foundation YXJL-2020-0972-1216Tianjin Health Science and Technology Project TJWJ2024MS023Tianjin Key Medical Discipline Construction Project TJYXZDXK-3-020c
6 · The paper itself

Abstract

objectiveTo develop and validate a simple intraoperative scoring system based on preoperative and cone-beam CT (CBCT) features for real-time prediction of objective response (OR) by mRECIST after DEB-TACE in patients with HCC. MATERIALS AND

methodsIn this single-center retrospective study, 274 patients (with a total of 386 HCC tumors) who underwent first-session DEB-TACE from 2022 to 2024 were included. CBCT was used to assess a 5-grade marginal contrast saturation (MCS), capsule presence, vascular lake phenomenon (VLP), and other candidate imaging features. Tumor response was assessed on contrast-enhanced CT using mRECIST. Analyses were performed on a tumor basis, with tumors assigned to development (n = 286) and validation (n = 100) sets by patient-level stratified randomization (7:3). Variables associated with OR were entered into a multivariable logistic regression; β coefficients were converted into a point-based score. Model performance was evaluated in terms of discrimination and calibration using the AUROC and the Hosmer-Lemeshow test.

resultsMost patients were male (78.8%), with a mean age of 62.5 ± 9.4 years. The median tumor diameter was 3.75 cm (interquartile range [IQR], 2.50-6.50 cm). The overall objective response rate (ORR) was 67.9% (262/386). Multivariable analysis revealed four independent predictors of OR: tumor diameter, capsule presence, VLP, and MCS grade. A 1-10-point score achieved excellent discrimination in the development set and maintained high performance in the validation set, with an AUROC of 0.93 (95% confidence interval [CI]: 0.86-0.99, goodness-of-fit p = 0.46).

conclusionAn imaging-only, intraoperative scoring system incorporating tumor size, capsule, VLP, and MCS accurately predicts short-term mRECIST response after DEB-TACE, facilitating rapid decision-making and subsequent patient management.

Indexed as

Carcinoma, HepatocellularChemoembolization, TherapeuticCone-Beam Computed TomographyLiver NeoplasmsAgedContrast MediaFemaleHumansMaleMiddle AgedRetrospective StudiesTreatment OutcomeContrast Mediacone‐beam computed tomographydrug‐eluting bead transarterial chemoembolizationhepatocellular carcinomaintraoperative imagingmarginal contrast saturation

Identifiers

PMID42332955
PMCPMC13287078

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.