Evidence map›Paper›PMID 42332133›Full record

ArticleScientific reports2026

A sonoelectric artificial meningeal device for enhanced implantable electric field ablation of glioblastoma.

Jie Li, Jiahao He, Jinliang Ren, Yiya Qiu, Xinyue Zhang, Jiaxin Huang, Xiaona Cao, Youliang Wu, Xudong Lin, Bingzhe Xu

Abstract read
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Jie Li *School of Biomedical Engineering, Sun Yat-Sen University, No. 135, Xingang Xi Road, Guangzhou, 510275, People's Republic of China.
Jiahao He *School of Biomedical Engineering, Sun Yat-Sen University, No. 135, Xingang Xi Road, Guangzhou, 510275, People's Republic of China.
Jinliang Ren *School of Biomedical Engineering, Sun Yat-Sen University, No. 135, Xingang Xi Road, Guangzhou, 510275, People's Republic of China.
Yiya QiuSchool of Biomedical Engineering, Sun Yat-Sen University, No. 135, Xingang Xi Road, Guangzhou, 510275, People's Republic of China.
Xinyue ZhangSchool of Biomedical Engineering, Sun Yat-Sen University, No. 135, Xingang Xi Road, Guangzhou, 510275, People's Republic of China.
Jiaxin HuangSchool of Biomedical Engineering, Sun Yat-Sen University, No. 135, Xingang Xi Road, Guangzhou, 510275, People's Republic of China.
Xiaona CaoSchool of Biomedical Engineering, Sun Yat-Sen University, No. 135, Xingang Xi Road, Guangzhou, 510275, People's Republic of China.
Youliang WuDepartment of Functional Neurosurgery, Second Affiliated Hospital of Guangzhou University of Chinese Medicine, 250 Changgang East, Haizhu District, Guangzhou, 510120, Guangdong, People's Republic of China.
Xudong LinSchool of Biomedical Engineering, Sun Yat-Sen University, No. 135, Xingang Xi Road, Guangzhou, 510275, People's Republic of China. linxd37@mail.sysu.edu.cn.
Bingzhe XuSchool of Biomedical Engineering, Sun Yat-Sen University, No. 135, Xingang Xi Road, Guangzhou, 510275, People's Republic of China. xubzh5@mail.sysu.edu.cn.

Funding

Guangdong Provincial Key Laboratory of Sensor Technology and Biomedical Instrument 2020B1212060077National Natural Science Foundation of China 32101160
6 · The paper itself

Abstract

Electric field tumor therapy has emerged as a promising non-invasive treatment for glioblastoma (GBM), but its clinical efficacy is severely limited by skull-induced attenuation of electric field intensity. To overcome this limitation, we developed a multilayer thin-film sonoelectric meningeal device (MF-SMD) consisting of an electrospun PLGA artificial meningeal scaffold integrated with a microneedle-based triboelectric film. This device converts externally applied low-intensity ultrasound into intracranial electric fields, enabling transcranial, localized, and controllable electric ablation of brain tumors. Upon low-intensity ultrasound excitation, the film generates localized intracranial electric fields that disrupt tumor mitosis while preserving neuronal integrity, and significantly reduce skull-induced field attenuation. In vitro and in vivo experiments validated the antitumor efficacy of the device, achieving approximately 68% proliferation inhibition in clinical GBM cell lines and a 72% reduction in tumor burden in orthotopic mouse models. Notably, compared with conventional tumor treating fields (TTF) systems that employ extracranial electrodes, the MF-SMD maintained electric field attenuation below 20% at therapeutic frequencies. These results establish a novel therapeutic paradigm that overcomes skull-induced electric field attenuation, addressing a key challenge in transcranial brain tumor therapy.

Indexed as

Brain NeoplasmsGlioblastomaAnimalsCell Line, TumorHumansMiceXenograft Model Antitumor AssaysArtificial dura materBrain tumorElectrospinningFunctional implantable deviceTumor treating fieldsUltrasound energy harvesting

Identifiers

PMID42332133
PMCPMC13575111

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.