Airborne spread of severe acute respiratory syndrome coronavirus 2 between rooms in a sealed, mechanically ventilated ward: Evidence from a hospital outbreak investigation.

Yo Ishigaki, Naohisa Fujita, Tatsuo Kato, Toshiya Ochiai, Haruo Kuroboshi, Akemi Sakane, Norio Asai

Abstract read
In one paragraph

Article in PloS one, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yo IshigakiResearch Center for Realizing Sustainable Societies, University of Electro-communications, Tokyo, Japan.ORCID https://orcid.org/0000-0001-7284-0381
Naohisa FujitaKyoto Okamoto Memorial Hospital, Kyoto, Japan.
Tatsuo KatoAir Purification Meister, Shinwa Corporation Co., Ltd., Tokyo, Japan.
Toshiya OchiaiNorth Medical Center Kyoto Prefectural University of Medicine, Kyoto, Japan.
Haruo KuroboshiNorth Medical Center Kyoto Prefectural University of Medicine, Kyoto, Japan.
Akemi SakaneNorth Medical Center Kyoto Prefectural University of Medicine, Kyoto, Japan.
Norio AsaiResearch Center for Realizing Sustainable Societies, University of Electro-communications, Tokyo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Airborne transmission of severe acute respiratory syndrome coronavirus 2 in enclosed, mechanically ventilated hospital wards remains poorly characterized. In February 2025, a coronavirus disease cluster involving 17 individuals occurred across multiple rooms in a sealed Japanese hospital ward. Several infected individuals had no documented close contact with the index patient, raising concerns about ventilation-related airflow-induced inter-room aerosol transmission. A multimodal environmental investigation was conducted via (1) CO2 decay experiments to quantify air change rates (ACHs), (2) particulate matter (PM)2.5 aerosol dispersion measurements using fog as a surrogate tracer, and (3) computational fluid dynamics (CFD) simulations to visualize airflow and scalar transport. Measurements were taken in the index room (Room A), corridor, and adjacent Rooms B-D under closed- and open-door conditions. Opening the patient room door significantly increased indoor ACHs (3.29/h → 4.01/h, p = 0.030) and allowed CO2 tracer gas to escape into the corridor. In the PM2.5 dispersion experiment, aerosols released in Room A were detected within the room, corridor, and neighboring rooms, with the highest out-of-room aerosol burden observed at the corridor sensor (area under the curve = 2.6 × 105 μg·s/m3). PM2.5 and PM10 concentrations were strongly correlated (r = 0.9997), revealing intermediate-sized particles capable of longer-range transport. CFD simulations reproduced key qualitative features of the experiments, including tracer accumulation within curtain-enclosed compartments, delayed leakage through the doorway, and downstream transport toward the corridor. Inter-room aerosol transport can occur in sealed, mechanically ventilated wards without natural ventilation or structural openings between rooms. Opening doors improves in-room ventilation and promotes aerosol leakage, revealing a trade-off between the dilution and contamination of shared spaces. Architectural elements such as privacy curtains contribute to airflow stagnation and uneven aerosol removal. Effective infection control strategies must incorporate airflow pathway management and localized filtration to prevent unintended aerosol migration in mechanically ventilated healthcare settings.

Indexed as

COVID-19SARS-CoV-2AerosolsAir MicrobiologyDisease OutbreaksHumansJapanParticulate MatterPatients' RoomsRespiration, ArtificialVentilationAerosolsParticulate Matter