Force systems of direct printed and thermoformed aligners with different trimlines during rotational movements: an in vitro analysis.

Emilia von Waldthausen, Lisa-Marie Mai, Philipp Meyer-Marcotty, Anja Quast, Jonas Q Schmid, Phillipp Brockmeyer, Wolfram Hahn, Bernhard Wiechens

Abstract readComparative Study
In one paragraph

Article in Progress in orthodontics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Emilia von Waldthausen *Department of Orthodontics, Universitätsmedizin Göttingen, Göttingen, Germany. emilia.waldthausen@med.uni-goettingen.de.
Lisa-Marie Mai *Department of Orthodontics, Universitätsmedizin Göttingen, Göttingen, Germany. lisa-marie.mai@med.uni-goettingen.de.ORCID https://orcid.org/0009-0006-3380-9844
Philipp Meyer-MarcottyDepartment of Orthodontics, Universitätsmedizin Göttingen, Göttingen, Germany.
Anja QuastDepartment of Orthodontics, Universitätsmedizin Göttingen, Göttingen, Germany.
Jonas Q SchmidDepartment of Orthodontics, University of Münster, Münster, Germany.
Phillipp BrockmeyerDepartment of Oral and Maxillofacial Surgery, Universitätsmedizin Göttingen, Göttingen, Germany.
Wolfram HahnDepartment of Orthodontics, Universitätsmedizin Göttingen, Göttingen, Germany.
Bernhard WiechensDepartment of Orthodontics, Universitätsmedizin Göttingen, Göttingen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe present study was conducted to quantify and compare the geometric accuracy and force application of thermoformed aligners (TFA) and direct-printed aligners (DPA) during mesial and distal rotation of a central upper incisor with a defined activation of 2°. METHODOLOGY: A 3D-printed model with a mounted central incisor was used to simulate 2° of rotational movement. Forces were recorded in three axes (Fx, Fy, Fz) over 60 minutes using a multi-axis force sensor. Three aligner types (thermoformed with straight trimline: TFAS, direct printed with straight trimline: DPAS, direct printed aligner with garlanded trimline: DPAG) were tested (n = 10 each). Vertical, transverse, and sagittal force components and their decrease were analyzed, and thickness measurements were taken.

resultsSignificant differences in resulting forces were observed between TFA, DPAS, and DPAG during both mesial and distal rotation. TFA generated significantly higher sagittal forces during mesial rotation (1.40 (0.30) N) compared to DPAS (-0.04 (0.05) N) and DPAG (0.11 (0.03) N; p < 0.001). Similar findings were observed for distal rotation (TFA 0.86 (0.16) N; DPAS -0.07 (0.06) N; DPAG 0.10 (0.09) N; p < 0.001). Transverse forces were generally lower, with only selected intergroup differences reaching significance. Time-resolved analysis revealed a pronounced initial force peak followed by continuous decay for TFA, while both DPA designs showed a gradual force increase with plateau formation. TFA showed the most pronounced material loss, whereas directly printed aligners most closely matched the planned thickness. In mesial rotation, significant group differences were found for facial (TFA: 0.42 (0.01) mm; DPAS: 0.71 (0.15) mm; DPAG: 0.63 (0.06) mm), incisal (0.60 (0.02) mm vs. 0.76 (0.11) mm vs. 0.65 (0.06) mm) and palatal surfaces (0.63 (0.01) mm vs. 0.94 (0.17) mm vs. 0.80 (0.06) mm; all p < 0.001). A comparable thickness pattern was observed for distal rotation.

conclusionThe results highlight the improved geometric accuracy and underscore the potential of 3D-printed aligners to improve force control and warrant further clinical investigation.

Indexed as

Orthodontic Appliance DesignOrthodontic Appliances, RemovablePrinting, Three-DimensionalTooth Movement TechniquesDental Stress AnalysisHumansIncisorIn Vitro TechniquesRotationDirect printed alignersForce decreaseGingival margin designOrthodonticsRotationThermoformed aligners