Evidence map›Paper›PMID 42326809›Full record

ArticlemedRxiv : the preprint server for health sciences2026

Computer Vision Scoring of Figure Copy and Recall.

David L Woods, Kathleen Hall, Isabella Jaramillo, Mike Blank, Kristin Geraci, Andrew Boghossian, Peter Pebler

Abstract readPreprint
In one paragraph

Article in medRxiv : the preprint server for health sciences, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

David L WoodsNeurobehavioral Systems, Inc., Berkeley, CA.ORCID 0000-0002-8804-3587
Kathleen HallNeurobehavioral Systems, Inc., Berkeley, CA.
Isabella JaramilloNeurobehavioral Systems, Inc., Berkeley, CA.
Mike BlankNeurobehavioral Systems, Inc., Berkeley, CA.
Kristin GeraciNeurobehavioral Systems, Inc., Berkeley, CA.
Andrew BoghossianNeurobehavioral Systems, Inc., Berkeley, CA.
Peter PeblerNeurobehavioral Systems, Inc., Berkeley, CA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: Figure copy and recall tests are sensitive measures of visuoconstruction and visual episodic memory, but their clinical is constrained by labor-intensive manual scoring. We developed and validated an automated, element-level scoring pipeline using Vertex AI object detection for the tablet-based figure copy and recall tasks in the California Cognitive Assessment Battery (CCAB). The automated scoring pipeline duplicated the scoring procedures used by expert manual raters. Methods: A normative sample of 2,011 community-dwelling adults aged 18-90 completed figure copy and delayed recall trials at baseline, with subsamples retested at 1 day and at 6, 18, and 30 months. Participants completed the drawings with their index finger on a tablet computer with finger position digitized to analyze the speed and timing of individual drawing strokes A convolutional object-detection model trained on the Vertex AI AutoML Vision platform identified each of twelve canonical figure elements in rendered drawings. Separate element presence and location scores were computed after homographically warping drawings onto a canonical template to produce trial-level Element, Location, and Total scores. To compare Vertex and human scores, Vertex AI and expert human raters independently scored 1500 randomly selected drawings to evaluate inter-rater agreement, including a common subset of 100 drawings scored by Vertex AI and all raters. Results: Total scores were virtually indistinguishable (r = 0.966) from human-human agreement (mean r = 0.971) as were Element presence scores (mean r = 0.959 vs. r = 0.963). Location-score agreement (r = 0.951) was slightly below the human-human mean (r = 0.972) due to pixel-level analysis by Vertex AI that was impossible for human raters. The Vertex pipeline showed no preferential advantage for the single expert rater who categorized Elements during training. Automated scores showed strong demographic gradients, age effects on Recall (r = -0.32) were approximately twice those in Copy conditions (r = -0.16). A Memory Cost score (Recall - Copy) showed a monotonic age-related decline from +0.40 z in the youngest subjects to -0.54 z in the oldest. Kinetic analysis revealed that drawing speed and efficiency showed significant age-related changes. Overnight test-retest reliability was high (Recall r = 0.72) and the Recall trial showed a large overnight learning effect (&[Delta] = +1.18) that continued with repeated tests up to 30 months (&[Delta] = +0.75). Conclusions: The computer vision pipeline described here preserves the element-level structure of expert manual scoring and recovers the memory-specific clinical signals of the delayed recall trial. Overall agreement with human rates was approximately an order of magnitude greater than previously described automated scoring approaches. Automatic, computer vision scoring of figure copy and delayed recall removes scoring barriers that impede the more extensive use of figure copy and recall tests.

Indexed as

automated scoringCalifornia Cognitive Assessment Batteryfigure drawingneuropsychological assessmentobject detectionvisual episodic memory

Identifiers

PMID42326809
PMCPMC13278209

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.