Evidence map›Paper›PMID 42326037›Full record

ArticleEuropean heart journal. Case reports2026

Multimodality approach to the no-entry ventricle for VT ablation: first European experience of the RA-to-LV percutaneous access-a case report.

Javier Sanaú, Julian Rodriguez García, Josep Comín-Colet, Ignasi Anguera, Paolo Domenico Dallaglio

Abstract readCase Reports
In one paragraph

Article in European heart journal. Case reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Javier SanaúArrhythmia Unit, Department of Cardiology, Hospital Universitari de Bellvitge, L'Hospitalet de Llobregat, Carrer Feixa Llarga s/n, Barcelona 08907, Spain.ORCID https://orcid.org/0009-0006-6246-8487
Julian Rodriguez GarcíaArrhythmia Unit, Department of Cardiology, Hospital Universitari de Bellvitge, L'Hospitalet de Llobregat, Carrer Feixa Llarga s/n, Barcelona 08907, Spain.
Josep Comín-ColetArrhythmia Unit, Department of Cardiology, Hospital Universitari de Bellvitge, L'Hospitalet de Llobregat, Carrer Feixa Llarga s/n, Barcelona 08907, Spain.ORCID https://orcid.org/0000-0001-8780-720X
Ignasi AngueraArrhythmia Unit, Department of Cardiology, Hospital Universitari de Bellvitge, L'Hospitalet de Llobregat, Carrer Feixa Llarga s/n, Barcelona 08907, Spain.ORCID https://orcid.org/0000-0001-6988-3487
Paolo Domenico DallaglioArrhythmia Unit, Department of Cardiology, Hospital Universitari de Bellvitge, L'Hospitalet de Llobregat, Carrer Feixa Llarga s/n, Barcelona 08907, Spain.ORCID https://orcid.org/0000-0002-3561-4163

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Catheter ablation of ventricular tachycardia (VT) in patients with both mechanical aortic and mitral valves remains challenging, as conventional retrograde or transseptal approaches are not feasible due to the risk of damaging prostheses. Alternative strategies such as thoracotomy, epicardial access, or stereotactic radiotherapy may be unsuitable due to anatomical or technical constraints. The right atrium-to-left ventricle (RA-to-LV) puncture through the inferoseptal process has recently emerged as a potential solution, yet real-world experience remains limited. Case summary: An 81-year-old man with rheumatic heart disease, double mechanical left-sided valve replacement, chronic kidney disease, and recurrent drug-refractory VT was referred for catheter ablation. Multimodal imaging using cardiac magnetic resonance and contrast-enhanced CT processed with ADAS3D software enabled identification of the arrhythmogenic substrate in the basal lateral LV and preprocedural planning of a safe puncture trajectory. Under general anaesthesia and uninterrupted anticoagulation, a percutaneous RA-to-LV puncture was performed with real-time guidance from electroanatomical mapping, CT-fluoroscopy integration, and intracardiac echocardiography. High-density mapping revealed a basal lateral scar with areas of conduction deceleration. Targeted ablation eliminated abnormal potentials and rendered VT non-inducible. A small restrictive iatrogenic Gerbode defect was observed without haemodynamic impact at 4-month follow-up echocardiogram. The patient recovered uneventfully and remained free of VT and ICD therapies at 5-month follow-up. Discussion: This case suggests that RA-to-LV access is feasible and safe in a highly selected patient when thorough multimodal planning is undertaken. This report represents the first European experience and supports the potential role of this technique in patients with no-entry ventricle.

Indexed as

AV septumCase reportMechanical valvesMultimodality imagingVentricular tachycardia ablation

Identifiers

PMID42326037
PMCPMC13281944

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.