Evidence map›Paper›PMID 42324425›Full record

SynthesisInternational journal of legal medicine2026

Micro-computed tomography for gunshot residue detection: A systematic review and meta-analysis of distance-dependent deposition patterns.

Carlos Antonio Vicentin-Junior, Raíssa Bastos Vieira, Luciana Munhoz, Plauto Christopher Aranha Watanabe, Carlos Eduardo Palhares Machado, Paulo Ricardo Martins-Filho

Abstract readSystematic ReviewMeta-AnalysisReview
In one paragraph

Synthesis in International journal of legal medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Carlos Antonio Vicentin-JuniorGraduate Program in Pathology, Department of Pathology and Legal Medicine, Ribeirão Preto Medical School, University of São Paulo, USP, Av. Bandeirantes 3900, 14049-900, Ribeirão Preto, Brazil. carlos.vicentin16@gmail.com.ORCID http://orcid.org/0009-0002-7706-1787
Raíssa Bastos VieiraGraduate Program in Pathology, Department of Pathology and Legal Medicine, Ribeirão Preto Medical School, University of São Paulo, USP, Av. Bandeirantes 3900, 14049-900, Ribeirão Preto, Brazil.ORCID http://orcid.org/0009-0003-2628-5171
Luciana MunhozDepartment of Stomatology, School of Dentistry, University of São Paulo, São Paulo, SP, Brazil.ORCID http://orcid.org/0000-0003-2375-5935
Plauto Christopher Aranha WatanabeDepartment of Stomatology, Public Oral Health, and Forensic Dentistry, Ribeirão Preto Dental School, University of São Paulo, Ribeirão Preto, Brazil.ORCID http://orcid.org/0000-0001-5524-1395
Carlos Eduardo Palhares MachadoGraduate Program in Pathology, Department of Pathology and Legal Medicine, Ribeirão Preto Medical School, University of São Paulo, USP, Av. Bandeirantes 3900, 14049-900, Ribeirão Preto, Brazil.ORCID http://orcid.org/0000-0002-0306-6211
Paulo Ricardo Martins-FilhoInvestigative Pathology Laboratory, Federal University of Sergipe, Sergipe, Brazil.ORCID http://orcid.org/0000-0001-8779-0727

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Micro-computed tomography (micro-CT) has emerged as a non-destructive technique for three-dimensional visualization of radiodense gunshot residue (GSR), yet its quantitative performance and variability have not been systematically evaluated. This systematic review and meta-analysis synthesized experimental evidence on micro-CT-based detection of inorganic GSR. Following PRISMA guidelines, six studies were included, of which four provided data for quantitative synthesis. Random-effects meta-analyses showed a progressive decline in detectable residue with increasing shooting distance, with pooled detection rates of 0.133% at 5 cm and 0.019% at 30 cm, accompanied by extreme between-study heterogeneity (I² > 99%). Quadratic mixed-effects meta-regression identified a significant nonlinear association between distance and detection, with a predicted maximum at approximately 17.79 cm, although distance explained only a small proportion of variability. Exploratory Gaussian modeling revealed marked substrate-dependent differences in detection profiles. Overall, micro-CT consistently enabled non-destructive three-dimensional localization and volumetric assessment of radiodense particles but showed limited capacity for standalone inferential applications, particularly shooting-distance estimation. These findings support its role as a complementary screening and mapping tool within forensic ballistic investigations while highlighting the need for standardized protocols and confirmatory compositional analyses. Clinical trial number: not applicable.

Indexed as

Forensic BallisticsWounds, GunshotX-Ray MicrotomographyHumansImaging, Three-DimensionalGunshot residueMethodological limitationsMicro-computed tomographyRadiodense particulatesVolumetric analysisX-ray microtomography

Identifiers

PMID42324425
PMCPMC13499849

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.