Evidence map›Paper›PMID 42324416›Full record

SynthesisJournal of robotic surgery2026

Perioperative outcomes of remote robot-assisted cholecystectomy: a single-arm meta-analysis.

Xin Peng, Zi-Yang Gan, Xin Jiang, Fang-Xing Peng

Erratum issuedAbstract readMeta-Analysis
PubMed Publisher
In one paragraph

Synthesis in Journal of robotic surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

4 authors.

Xin Peng *North Sichuan Medical College, Nanchong, Sichuan, China.
Zi-Yang Gan *North Sichuan Medical College, Nanchong, Sichuan, China.
Xin JiangNorth Sichuan Medical College, Nanchong, Sichuan, China.
Fang-Xing PengNorth Sichuan Medical College, Nanchong, Sichuan, China. 3847438748@qq.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Remote robot-assisted cholecystectomy is an emerging technology integrating 5G communication and robotic surgical systems, but its perioperative outcomes have not been systematically evaluated. This single-arm meta-analysis aimed to assess the feasibility, safety, and key perioperative parameters of this technique. A systematic search was performed in PubMed, Embase, Web of Science, and Cochrane CENTRAL from inception to May 1, 2026. All original studies (case series, cohort studies) reporting perioperative outcomes of remote robot-assisted cholecystectomy were included, regardless of whether a control arm was present (control-arm data were not used for pooling). A random-effects model was used to pool continuous variables (weighted mean difference) and binary variables (proportions). Pre-planned subgroup analyses (by country, publication time, robotic system type, study design) and leave-one-out sensitivity analyses were conducted. Nine studies involving 216 patients (from China, Italy, the United States, Germany, and the Netherlands) were included. The main pooled results were as follows: surgical success rate, 98% (95% CI: 0.98-1.00) with very low heterogeneity (I² = 0.3%); total operative time, 98.75 min (95% CI: 66.62-130.88 min), high heterogeneity (I² = 98.6%); robotic operative time, 64.91 min (95% CI: 44.77-85.06 min), high heterogeneity (I² = 97.6%); robotic setup time, 20.12 min (95% CI: 14.23-26.00 min), high heterogeneity (I² = 99.1%); length of hospital stay, 2.85 days (95% CI: 2.24-3.46 days), high heterogeneity (I² = 96.6%); estimated blood loss (2 studies), 22.39 mL (95% CI: 6.42-38.36 mL), high heterogeneity (I² = 98.8%). Subgroup analyses showed that robotic setup time was significantly shorter in studies published in or after 2008 (P = 0.015) and in prospective studies (P < 0.001). No significant differences were found in other subgroups (country, robotic system type, study design) for any outcome. Leave-one-out sensitivity analyses confirmed the robustness of all pooled results. Given the single-arm design and the absence of a concurrent control group, all comparisons with on-site robotic surgery are descriptive and hypothesis-generating only. This single-arm meta-analysis provides the first quantitative synthesis of existing evidence on remote robot-assisted cholecystectomy. The technique achieves a high surgical success rate of 98%, and perioperative outcomes (operative time, setup time, hospital stay, blood loss) are fall within range of historical data for on-site robotic cholecystectomy. Setup time has shown a significant decreasing trend in recent years. Although the included studies are mostly small and exhibit high heterogeneity, the available evidence supports good feasibility and early safety of remote robotic cholecystectomy. Large-scale prospective studies and randomized controlled trials are needed to confirm non-inferiority.

Indexed as

CholecystectomyRobotic Surgical ProceduresFeasibility StudiesHumansLength of StayOperative TimeTreatment Outcome5GCholecystectomyPerioperative outcomesRobot-assisted surgerySingle-arm meta-analysisTelesurgery

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.