ArticleSurgical endoscopy2026
Quantitative optimisation of indocyanine green fluorescence for parathyroid imaging in robotic BABA thyroidectomy: a prospective cohort study.
Article in Surgical endoscopy, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
objectiveTo develop and validate a quantitative framework for intraoperative indocyanine green (ICG) fluorescence imaging of the parathyroid glands during robotic bilateral axillo-breast approach (BABA) thyroidectomy and to identify technical and clinical factors associated with optimal image quality.
backgroundICG fluorescence is increasingly used to aid parathyroid identification and perfusion assessment in thyroid surgery, but there is no consensus on optimal dosing, image quantification, or patient selection, particularly in the context of robotic thyroidectomy. A robust, objective definition of "good" imaging is needed to standardise protocols and support broader clinical adoption.
methodsIn this single-centre prospective study (June 2024-January 2025), 72 consecutive patients with low-risk papillary thyroid carcinoma underwent robotic BABA thyroidectomy with ICG fluorescence using the da Vinci Xi system. A cyclic dosing protocol (1.5, 2.0, 2.5, 3.0 mL) was applied in eligible cases. For each patient, a 12-s fluorescence sequence was recorded from the onset of visible ICG uptake, and 12 frames (1 frame per second) were extracted. In each frame, the parathyroid region (Zone A) and periparathyroid background (Zone C) were manually segmented, and the relative fluorescence intensity ratio (RFIR = A/C) was calculated. Image quality was independently graded on a 3-point scale (0-2) and classified as clear (mean score ≥ 1) or unclear (< 1). Receiver operating characteristic analysis was used to derive an RFIR threshold for "good" imaging. Univariable and multivariable logistic regression were performed to explore associations between imaging quality and clinical variables (demographics, biochemistry, thyroiditis, fasting blood glucose [FBG], intraoperative haemodynamics) and ICG dose.
resultsAn RFIR cut-off of 1.07 yielded an area under the curve of 0.832 for discrimination between clear and unclear images. At the case level, imaging was defined as good when at least 6 of 12 frames (≥ 50%) had RFIR ≥ 1.07. In univariable analysis, higher body mass index was positively associated with good imaging (odds ratio [OR] 1.18, 95% confidence interval [CI] 1.03-1.36; P = 0.020), whereas an ICG dose of 3.0 mL was negatively associated (OR 0.11, 95% CI 0.02-0.50; P = 0.004). In multivariable analysis, elevated FBG (OR 0.25, 95% CI 0.08-0.86; P = 0.027) and an ICG dose of 3.0 mL (OR 0.01, 95% CI 0.00-0.17; P = 0.001) remained independently associated with reduced odds of good imaging, while other clinical and haemodynamic variables were not significant. Interaction analyses showed that low FBG combined with lower doses (1.5-2.0 mL) provided the highest predicted probability of optimal imaging, whereas high FBG with higher doses (2.5-3.0 mL) yielded the poorest performance.
conclusionsICG fluorescence imaging of the parathyroid glands during robotic BABA thyroidectomy can be standardised using an RFIR threshold of 1.07 and a frame-based majority rule to define good imaging. Lower ICG doses (1.5-2.0 mL) and favourable metabolic status (low FBG) are key determinants of optimal image quality, whereas higher doses (3.0 mL) and elevated FBG are associated with over-saturation and reduced contrast. These findings support tailored, low-dose ICG protocols and provide a quantitative benchmark for future multi-centre studies linking fluorescence metrics to postoperative calcium and parathyroid function outcomes.