Evidence map›Paper›PMID 42321673›Full record

ArticleBMC medical imaging2026

FD-MSP: feature decoupling network with multi-scale prototypes for domain-adaptive polyp segmentation.

Wenqi Zhong, Xu Yang, Shengyuan Liu, Yapeng Wang, Sio-Kei Im

Abstract read
In one paragraph

Article in BMC medical imaging, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Wenqi ZhongFaculty of Applied Sciences, Macao Polytechnic University, Macao SAR, China.
Xu YangFaculty of Applied Sciences, Macao Polytechnic University, Macao SAR, China. xuyang@mpu.edu.mo.
Shengyuan LiuDepartment of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China.
Yapeng WangFaculty of Applied Sciences, Macao Polytechnic University, Macao SAR, China.
Sio-Kei ImFaculty of Applied Sciences, Macao Polytechnic University, Macao SAR, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Polyp segmentation in colonoscopy images plays a critical role in the early detection and treatment of colorectal cancer. Although deep learning-based segmentation models have achieved remarkable success, their performance is often limited by variable imaging protocols or unseen datasets from different endoscopic devices. To address this challenge, unsupervised domain adaptation (UDA) methods have emerged as a promising solution, leveraging labeled source data and unlabeled target data to bridge the domain gap. However, existing UDA models suffer from two key limitations. First, they entangle domain-invariant and domain-specific features, making it difficult to identify which representations should transfer across domains. Second, they rely on single-scale features that fail to capture the extreme size variations observed in polyps, which range from tiny flat lesions to large protruding masses. As such, we propose FD-MSP, a feature decoupling network with multi-scale prototypes for cross-domain polyp segmentation. The core contribution is a structural redesign of the UDA pipeline that explicitly decouples feature distribution alignment from multi-scale semantic prototype learning, rather than entangling them in a single objective. This redesign is realized through four tightly-coupled components: (i) a dual-stream shallow-encoder decoupling module that separates domain-invariant polyp signatures from equipment-dependent variations through the joint effect of adversarial alignment on both low-level features and output predictions and a pixel-wise orthogonality regularizer between source-fed and target-fed shallow features; (ii) an online pseudo-fusion adapter that blends offline soft labels with current full-image predictions under class-wise confidence gating; (iii) a multi-scale grouped prototype layer (three groups of seven prototypes) that captures polyp patterns at multiple granularities through dilated convolutions with progressively expanding receptive fields; and (iv) a dual-branch gated head that adaptively fuses convolutional and prototype predictions at inference. Experimental results on three public colonoscopy datasets showed that FD-MSP offers consistent improvements over existing UDA methods for polyp segmentation performance in the target domain.

Indexed as

Colonic PolypsColonoscopyDeep LearningImage Interpretation, Computer-AssistedAlgorithmsHumansDecoupled networksDomain adaptationPolyp segmentationPrototype learning.

Identifiers

PMID42321673
PMCPMC13584388

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.