Evidence map›Paper›PMID 42319812›Full record

ArticleJMIR medical informatics2026

Differentiating Ischemic From Nonischemic T-Wave Inversion Using a Multimodal Vision-Language Model With Reinforcement Learning (ECG-R1): Development and Validation Study.

Yunzhang Cheng, Zhongkai Wang, Wen Zhang, Qin Zhang, Mingwei Zhang, Songbin Cai, Tianyi Zhang

Abstract readValidation Study
In one paragraph

Article in JMIR medical informatics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yunzhang Cheng *School of Health Science and Engineering, University of Shanghai for Science and Technology, Room 1002, 10th Floor, Zhuoyue Building, No. 334 Jungong Road, Shanghai, Yangpu District, 200093, China, +86 18566664556.ORCID 0009-0006-3859-4598
Zhongkai WangDepartment of Cardiovasology, Changhai Hospital, Shanghai, Shanghai, China.ORCID 0009-0005-0037-586X
Wen Zhang *School of Health Science and Engineering, University of Shanghai for Science and Technology, Room 1002, 10th Floor, Zhuoyue Building, No. 334 Jungong Road, Shanghai, Yangpu District, 200093, China, +86 18566664556.ORCID 0009-0009-7215-8708
Qin ZhangDepartment of Cardiovasology, Changhai Hospital, Shanghai, Shanghai, China.ORCID 0000-0002-2209-252X
Mingwei ZhangSchool of Health Science and Engineering, University of Shanghai for Science and Technology, Room 1002, 10th Floor, Zhuoyue Building, No. 334 Jungong Road, Shanghai, Yangpu District, 200093, China, +86 18566664556.ORCID 0000-0002-4388-2838
Songbin CaiXin Hua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China.ORCID 0000-0003-0564-6284
Tianyi ZhangSchool of Health Science and Engineering, University of Shanghai for Science and Technology, Room 1002, 10th Floor, Zhuoyue Building, No. 334 Jungong Road, Shanghai, Yangpu District, 200093, China, +86 18566664556.ORCID 0009-0007-9209-8840

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The differentiation of primary ischemic from secondary nonischemic T-wave inversion (TWI) on electrocardiograms (ECGs) presents a critical and pervasive diagnostic challenge in emergency cardiology. Historical clinical literature reports that clinician-led visual interpretation of isolated TWI yields a positive predictive value of only approximately 50% due to profound morphological ambiguity. This high degree of uncertainty frequently leads to high false-positive rates, resulting in unnecessary, costly, and potentially risky invasive angiographic procedures for patients. Furthermore, although existing deep learning models have attempted to address this clinical bottleneck, they are frequently limited to single-modality, "black box" architectures. Their inability to process complex multimodal data or provide transparent reasoning traces fundamentally limits clinical trust and real-world adoption. Objective: The objective of this study was to develop a novel diagnostic framework designed to address the critical clinical challenge of accurately differentiating ischemic from nonischemic TWI. By using a multimodal vision-language model trained with a reinforcement learning (RL) paradigm, this study aimed to improve diagnostic accuracy and provide interpretable reasoning. Methods: We developed ECG-R1, a multimodal framework using the Qwen2-VL-2B vision-language model, to analyze ECG waveform images and associated clinical text. Instead of supervised fine-tuning (SFT), the model was trained using an RL paradigm with the group relative policy optimization algorithm. The model was trained to generate a structured output containing an explicit reasoning trace and a final "yes" or "no" answer. A 2-component, rule-based reward function was designed to assess format adherence and diagnostic accuracy. Performance was compared against strong SFT baselines. Results: Evaluated on a large-scale multimodal dataset of 12,917 TWI cases, our ECG-R1 model achieved a state-of-the-art in-domain accuracy of 75.21%, a sensitivity of 82.55%, and an area under the receiver operating characteristic curve of 84.18%. The model demonstrated robust cross-hospital generalization, maintaining a 72.93% out-of-domain accuracy and an 81.56% area under the receiver operating characteristic curve. When controlling for model scale, the RL paradigm yielded substantial absolute improvements of 6.69% in in-domain performance and a substantial 11.48% improvement in out-of-domain performance over the capacity-matched Qwen2-VL-2B full-FT baseline. These results suggested that the RL approach was superior for learning invariant physiological features rather than overfitting to source-domain artifacts. Conclusions: The RL-based ECG-R1 framework significantly outperformed capacity-matched SFT baselines in both diagnostic accuracy and cross-domain robustness. By explicitly modeling interpretable clinical reasoning and using probabilistic diagnostic language to prevent premature cognitive closure, ECG-R1 may serve as a highly transparent clinical decision support system. It was structurally designed to safely assist cardiologists within a strict human-in-the-loop paradigm, establishing a robust foundation for prospective clinical trials.

Indexed as

ElectrocardiographyMyocardial IschemiaDiagnosis, DifferentialHumansReinforcement Machine LearningAIartificial intelligencecomputer-aided diagnosisECGelectrocardiogrammultimodal artificial intelligencemyocardial ischemiareinforcement learningT-wave inversionvision-language models

Identifiers

PMID42319812
PMCPMC13281817

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.