Evidence map›Paper›PMID 42319669›Full record

ArticleRadiological physics and technology2026

Establishing discard criteria for lead aprons using deep learning-based quantification of defect area on X-ray fluoroscopic video.

Koichi Hanada, Haruka Suzuki, Masato Takahashi, Hiraku Fuse, Manamu Kimura, Kota Sasaki, Kenji Yasue, Hiroki Nosaka, Shin Miyakawa, Norikazu Koori

Erratum issuedAbstract read
PubMed Publisher
In one paragraph

Article in Radiological physics and technology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

10 authors.

Koichi HanadaDepartment of Radiological Sciences, Ibaraki Prefectural University of Health Sciences, 4669‑2, Ami, Inashiki, 300‑0394, Ibaraki, Japan. hanadako@ipu.ac.jp.ORCID http://orcid.org/0000-0002-8844-3353
Haruka SuzukiDepartment of Radiological Sciences, Ibaraki Prefectural University of Health Sciences, 4669‑2, Ami, Inashiki, 300‑0394, Ibaraki, Japan.
Masato TakahashiDepartment of Radiological Sciences, Ibaraki Prefectural University of Health Sciences, 4669‑2, Ami, Inashiki, 300‑0394, Ibaraki, Japan.ORCID http://orcid.org/0009-0004-7437-6665
Hiraku FuseDepartment of Radiological Sciences, Ibaraki Prefectural University of Health Sciences, 4669‑2, Ami, Inashiki, 300‑0394, Ibaraki, Japan.
Manamu KimuraDepartment of Radiology, Tsuchiura Kyodo General Hospital, 4-1-1 Otsuno, Tsuchiura, 300-0028, Ibaraki, Japan.
Kota SasakiDepartment of Radiological Sciences, Ibaraki Prefectural University of Health Sciences, 4669‑2, Ami, Inashiki, 300‑0394, Ibaraki, Japan.
Kenji YasueDepartment of Radiological Sciences, Ibaraki Prefectural University of Health Sciences, 4669‑2, Ami, Inashiki, 300‑0394, Ibaraki, Japan.ORCID http://orcid.org/0000-0001-6655-6106
Hiroki NosakaDepartment of Radiological Sciences, Ibaraki Prefectural University of Health Sciences, 4669‑2, Ami, Inashiki, 300‑0394, Ibaraki, Japan.
Shin MiyakawaDepartment of Radiological Sciences, Ibaraki Prefectural University of Health Sciences, 4669‑2, Ami, Inashiki, 300‑0394, Ibaraki, Japan.
Norikazu KooriDepartment of Radiological Technology, Niigata University of Health and Welfare, 1398 Shimami-cho, Niigata City, 950-3198, Niigata, Japan.ORCID http://orcid.org/0000-0003-1086-3945

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To establish an objective discard framework for lead aprons, defect areas quantified from X-ray fluoroscopy videos were linked to their corresponding dosimetric impacts. A fine-tuned YOLOv8 instance segmentation model, achieving an average precision at an intersection-over-union threshold of 0.5 (AP@0.5) of 0.457, was employed to analyze fluoroscopic videos of 18 aprons with 0.25 mmPb equivalence. The model enabled automated defect detection and area estimation with a video processing time of 15 s. Dosimetry experiments mimicking endoscopic retrograde cholangiopancreatography (ERCP) conditions were conducted using an anthropomorphic phantom and apron samples with slit defects of varying widths. The results indicated that the transmitted dose increased linearly with defect area under all tested conditions. Based on weighted least-squares analysis of covariance (WLS-ANCOVA), slit widths of 1.0, 2.0, and 3.5 mm were pooled for modeling, as they exhibited similar dosimetric behavior. A linear model was applied to relate defect area to the increase in transmitted dose, defining the discard threshold as the minimum area at which the upper one-sided 95% prediction limit reached a specified dose limit. Given a baseline dose of 2.38 mSv after transmission through the apron without defects and a regulatory dose limit of 5 mSv per 3 months, the discard threshold for slit-like defects was determined to be 2.87 cm

Indexed as

Deep LearningImage Processing, Computer-AssistedLeadRadiation ProtectionVideo RecordingDetection AlgorithmsFluoroscopyPhantoms, ImagingRadiation DosageRadiometryX-RaysLeadDeep learningDiscard criteriaDosimetryFluoroscopy videoLead apronRadiation protection

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.