Evidence map›Paper›PMID 42317594›Full record

ArticlePlastic and reconstructive surgery. Global open2026

The Role of Flow Couplers in Free Flap Monitoring: Evidence From a Systematic Review and Meta-analysis.

Laura De Pellegrin, Léna G Dietrich, Marcus Wölffer, Radu Olariu, Cédric Zubler, Ioana Lese

Abstract read
In one paragraph

Article in Plastic and reconstructive surgery. Global open, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Laura De PellegrinFrom the Department of Plastic and Hand Surgery, Inselspital University Hospital Bern, University of Bern, Bern, Switzerland.
Léna G DietrichFrom the Department of Plastic and Hand Surgery, Inselspital University Hospital Bern, University of Bern, Bern, Switzerland.
Marcus WölfferFrom the Department of Plastic and Hand Surgery, Inselspital University Hospital Bern, University of Bern, Bern, Switzerland.
Radu OlariuFrom the Department of Plastic and Hand Surgery, Inselspital University Hospital Bern, University of Bern, Bern, Switzerland.
Cédric ZublerFrom the Department of Plastic and Hand Surgery, Inselspital University Hospital Bern, University of Bern, Bern, Switzerland.
Ioana LeseFrom the Department of Plastic and Hand Surgery, Inselspital University Hospital Bern, University of Bern, Bern, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Flow couplers (FCs) are increasingly used in microsurgical free tissue transfer to provide continuous, real-time monitoring of venous outflow at the anastomotic site. This systematic review and meta-analysis evaluates the clinical performance of FCs, focusing on diagnostic accuracy and flap outcomes compared with conventional monitoring techniques. Methods: A systematic search of PubMed, Web of Science, and the Cochrane Library was conducted through November 1, 2025, following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Clinical studies reporting FC use in free flap reconstruction were included. Data on flap survival, venous thrombosis, complications, and FC diagnostic performance were extracted. Meta-analyses were performed to calculate pooled sensitivity, specificity, and flap failure rates. Results: Eleven studies including 1775 free flaps (876 monitored with FCs) met inclusion criteria. Pooled sensitivity and specificity for detecting flap compromise were 96.5% and 90.9%, respectively. Flap failure occurred in 2.2% of FC-monitored flaps versus 3.1% in controls. FCs showed a high negative predictive value but variable positive predictive value, with false-positive signal losses being frequently caused by technical issues rather than true thrombosis. False negatives were uncommon. Compared with traditional monitoring methods, FCs provided superior continuous venous assessment. Conclusions: FCs are highly sensitive tools for early detection of venous compromise in free flap surgery, particularly in buried reconstructions. However, limited specificity and inability to detect arterial insufficiency support the use of multimodal monitoring strategies. Standardized protocols and technical expertise are essential to minimize false positives and optimize flap monitoring outcomes.

Identifiers

PMID42317594
PMCPMC13275153

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.