ArticleFrontiers in surgery2026
Application of a self-developed femoral artery compression hemostasis device in proximal femoral nail anti-rotation surgery for intertrochanteric fractures: a case report.
Article in Frontiers in surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Intertrochanteric fractures of the femur are a prevalent type of hip fracture among the elderly. While surgical treatment is the preferred approach for managing these fractures, conventional tourniquets cannot be applied in hip surgery due to anatomical constraints. As a result, effectively controlling intraoperative and perioperative blood loss has long posed a significant clinical challenge. Case presentation: A 70-year-old male patient with a comminuted fracture in the left intertrochanteric region of the femur underwent closed reduction and internal fixation using a proximal femoral nail anti-rotation (PFNA). During the procedure, a proprietary compression-type femoral artery hemostasis device was used to effectively control regional blood flow. The femoral artery pulsation was palpated inferior to the inguinal ligament and superior to the pubic ramus. A compression device was then applied to achieve precise compression of the femoral artery. Effective compression was indicated by the absence of the dorsalis pedis artery pulse, which helped maintain collateral circulation. The procedure lasted 45 min, with an estimated intraoperative visible blood loss of 50 mL. Quantitative analysis using the Gross formula, based on the patient's hematocrit decline from 0.394 preoperatively to 0.358 on postoperative day 2, revealed a calculated total perioperative blood loss of 433 mL, with hidden blood loss accounting for 383 mL. There were no postoperative complications, including limb ischemia, nerve injury, or deep vein thrombosis. The patient was discharged in good condition 6 days after surgery. A follow-up examination at 6 weeks postoperatively revealed satisfactory callus formation at the fracture site and stable internal fixation. Conclusion: In this single case, application of the self-developed femoral artery compression hemostatic device was associated with reduced intraoperative blood loss and a favorable safety profile during PFNA fixation of an intertrochanteric fracture. The device may offer a novel, non-invasive hemostatic strategy for selected hip fracture surgeries; however, further studies are required to confirm its efficacy and safety.