ArticleClinical oral investigations2026
Deflection of occlusal splints under bruxism-like conditions: An exploratory in vitro investigation.
Article in Clinical oral investigations, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveOcclusal splints are common part of bruxism management to reduce occlusal forces. This preliminary study investigates in vitro the deflection of occlusal splint materials. MATERIALS AND
methodsTwo occlusal splints per material were fabricated by casting (Palapress vario), thermoforming (Erkodur 1.0 mm and 1.5 mm), milling (Bio Splint P HI, Bio Splint C, ClearSplint), and 3D printing (LuxaPrint Ortho Plus, 0° and 45° orientation). Each splint was applied to a functional dental model featuring movable plastic teeth. The right upper incisor, canine, and second premolar were loaded up to 50 N on occlusal and buccal sides using a universal testing machine (Z010, Zwick; four measurements). Statistical analysis used Kruskal-Wallis and Dunn's test with Bonferroni correction (α = 0.05).
resultsMean deflection of the tooth-splint-system ranged from 0.8 mm to 2.7 mm. Significant differences between the materials were detected (p < 0.001), with the highest values for Erkodur 1.0 mm and ClearSplint and the lowest for Bio Splint P HI and Erkodur 1.5 mm. No significant differences were observed between the two print orientations of LuxaPrint Ortho Plus.
conclusionsThis preliminary study demonstrates material-dependent differences in the deflection of occlusal splints under load. Clinically oriented test setups may provide valuable insight for evidence-based material selection in bruxism management.
Indexed as
Identifiers
42315673What OpenQuestion holds