Evidence map›Paper›PMID 42315663›Full record

ArticleArchives of orthopaedic and trauma surgery2026

Radiographic assessment of femoral, acetabular and global offset following hip spacer implantation in staged total hip arthroplasty".

Luca Cavagnaro, Emilio Ferrari, Valentina Providenti, Vito Marciante, Giuliana Carrega, Matteo Formica

Abstract read
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Luca CavagnaroJoint Replacement Unit/Bone Infection Unit (MIOS)-Ospedale Santa Maria di Misericordia, Via Martiri della Foce 40, 17031, Albeng, SV, Italy. lucacavagnaro87@gmail.com.
Emilio FerrariJoint Replacement Unit/Bone Infection Unit (MIOS)-Ospedale Santa Maria di Misericordia, Via Martiri della Foce 40, 17031, Albeng, SV, Italy.
Valentina ProvidentiJoint Replacement Unit/Bone Infection Unit (MIOS)-Ospedale Santa Maria di Misericordia, Via Martiri della Foce 40, 17031, Albeng, SV, Italy.
Vito MarcianteClinica Ortopedica-Policlinico San Martino, Largo Rosanna Benzi 10, 16132, Genoa, GE, Italy.
Giuliana CarregaJoint Replacement Unit/Bone Infection Unit (MIOS)-Ospedale Santa Maria di Misericordia, Via Martiri della Foce 40, 17031, Albeng, SV, Italy.
Matteo FormicaClinica Ortopedica-Policlinico San Martino, Largo Rosanna Benzi 10, 16132, Genoa, GE, Italy. matteo.formica@unige.it.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe number of total hip arthroplasties (THAs) performed worldwide is steadily increasing, and, consequently, the demand for revision procedures is expected to rise as well. two-stage revision procedure continues to be considered the gold standard in many clinical scenarios. During the first step, failure to restore femoral offset has been implicated as a contributor to instability and mechanical failure, although a clear consensus is still lacking.

objectivesThe primary aim of this study is to evaluate the restoration of biomechanical parameters of the hip-specifically leg length discrepancy (LLD), femoral offset (FO), acetabular offset (AO), and global offset (GO)-following implantation of a specific type of articulating hip spacer during the first stage of a two-stage revision for PJI. A secondary objective is to assess the correlation between variations in offset parameters and the rate of interstage mechanical complications. MATERIALS AND

methodsWe retrospectively reviewed all patients undergoing staged revision with a specific articulating spacer between 2020 and 2022 at a single institution. Harris Hip Scores, Oxford Hip Scores, and Visual Analogue Scales for pain were obtained at different time points. Radiographic analysis included LLD, FO, AO and GO measurements on the affected (spacer and post-reimplantation) and the contralateral side. Complications were recorded during the interstage and post-reimplantation period.

resultsForty-seven patients (47 hips), were enrolled. The mean follow-up was 25.3 months. Clinical outcomes showed significant improvement from pre-operative visit to interim period and at the last follow-up (p < 0.01). No statistically significant differences for FO, AO and GO between contralateral and spacer side were observed. LLD before reimplantation was 10.1 ± 7.5 mm. GO increased of 4 ± 3.2 mm at final follow-up (p < 0.05) with a final LLD of 5.6 ± 4.9 mm. Six complications (12.8%) occurred during the interstage period: 4 spacer dislocations (8.5%) and 2 intraoperative femoral peri-spacer fractures (4.3%). Comparison between stable and dislocated spacers showed statistically significant differences for mean ΔFO (p = 0.02) and ΔGO (p = 0.04).

conclusionThe articulated spacer assessed in this study, especially when used in combination with a custom-made acetabular component, allowed approximation of the main biomechanical parameters, with small, non-significant differences compared to the contralateral side. Offset parameters reduction may be associated with spacer dislocation rate.

Indexed as

AcetabulumArthroplasty, Replacement, HipFemurHip JointHip ProsthesisAgedBiomechanical PhenomenaFemaleHumansLeg Length InequalityMaleMiddle AgedProsthesis FailureRadiographyReoperationRetrospective StudiesComplicationHipPJIRevisionSpacerTwo-stage

Identifiers

PMID42315663
PMCPMC13279739

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.