Evidence map›Paper›PMID 42315626›Full record

ArticleArchives of orthopaedic and trauma surgery2026

Is a central cavity necessary for bioactive glass-ceramic spacers in plated ACDF? A retrospective comparison of solid versus cavity designs.

Tae Hoon Kang, Geumho Lee, Byungjun Kang, Jeongwoon Han, Minjoon Cho, Jae Hyup Lee

Abstract readComparative Study
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Tae Hoon Kang *Department of Orthopedic Surgery, College of Medicine, Seoul National University, Seoul, Korea, Republic of.ORCID http://orcid.org/0000-0003-0127-9456
Geumho Lee *Department of Orthopedic Surgery, Daniel Medical Center, Bucheon, Korea, Republic of.
Byungjun KangDepartment of Orthopedic Surgery, Plus Orthopedic hospital, Incheon, Korea, Republic of.
Jeongwoon HanDepartment of Orthopedic surgery, Sungae hospital, Seoul, Korea, Republic of.
Minjoon ChoDepartment of Orthopedic Surgery, College of Medicine, Seoul National University, Seoul, Korea, Republic of.
Jae Hyup LeeDepartment of Orthopedic Surgery, College of Medicine, Seoul National University, Seoul, Korea, Republic of. spinelee@snu.ac.kr.ORCID https://orcid.org/0000-0002-2141-0266

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTraditionally, interbody cages feature a central cavity for graft packing. However, for bioactive glass-ceramic (BGS-7) spacers achieving fusion via surface-mediated osseointegration, this cavity may be biologically redundant and structurally disadvantageous. We compared radiological and clinical outcomes of plated anterior cervical discectomy and fusion (ACDF) using BGS-7 spacers with or without a central cavity.

methodsWe retrospectively reviewed patients undergoing plated ACDF using solid non-cavity (17 patients, 24 levels) or central-cavity (17 patients, 33 levels) BGS-7 spacers. Radiographic fusion was evaluated using dynamic interspinous distance (primary, ≤ 2 mm) and segmental angular motion (secondary, ≤ 4°), alongside CT-based osseointegration (direct contact ≥ 50%). Subsidence (≥ 2 mm) and clinical outcomes were evaluated at 12 months.

resultsBoth groups demonstrated comparable 12-month clinical improvements (p > 0.05). Radiographic fusion rates were equivalent between non-cavity and central-cavity groups based on the primary distance (91.7% vs. 84.8%, p = 0.687) and secondary angular criteria (79.2% vs. 63.6%, p = 0.331). The non-cavity group showed a trend toward superior segmental stability, with a smaller dynamic gap distance (0.82 ± 0.64 mm vs. 1.53 ± 1.99 mm, p = 0.064). CT-based fusion perfectly matched (90.5% vs. 90.9%, p = 1.000). Subsidence rates were comparably low (12.5% vs. 12.1%), with no spacer breakage.

conclusionsIn plated ACDF, adding a central cavity to BGS-7 spacers confers no measurable advantage over the solid design. Solid spacers inherently preserve maximum endplate contact area for optimal load-sharing and surface-mediated fusion. Eliminating the cavity and supplemental grafts avoids logical redundancy, donor-site morbidity, and unnecessary healthcare costs.

Indexed as

CeramicsCervical VertebraeDiskectomySpinal FusionFemaleGlassHumansMaleOsseointegrationProsthesis DesignRetrospective StudiesGlass ceramicsAnterior cervical discectomy and fusionBioactive glass-ceramicBiocompatible materialsInterbody cageProsthesis designSpinal fusion

Identifiers

PMID42315626
PMCPMC13279369

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.