Evidence map›Paper›PMID 42315545›Full record

ArticleScientific reports2026

Investigation of the lower block rows in the King's Chamber of the Great Pyramid using ultrasonic testing with shear wave arrays.

Benedikt Maier, Amr G Hamza, Alejandro Ramirez-Pinero, Khaled Taie, Thomas Schumacher, Olga Popovych, Mohamed Elkarmoty, Mehdi Tayoubi, Hany Helal, Christian U Grosse

Abstract read
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Benedikt MaierChair of Non-Destructive Testing, TUM School of Engineering and Design, Technical University of Munich, Lichtenbergstr. 2, Garching, 85748, Germany. benedikt.maier@tum.de.
Amr G HamzaDepartment of Mining, Petroleum, and Metallurgical Engineering, Faculty of Engineering, Cairo University, Gamaa Street 1, Giza, 12613, Egypt.
Alejandro Ramirez-PineroChair of Non-Destructive Testing, TUM School of Engineering and Design, Technical University of Munich, Lichtenbergstr. 2, Garching, 85748, Germany.
Khaled TaieRock Engineering Laboratory, Faculty of Engineering, Cairo University, Gamaa Street 1, Giza, 12613, Egypt.
Thomas SchumacherCivil and Environmental Engineering, Portland State University, 1930 SW 4Th Avenue, Portland, 97201, OR, USA.
Olga PopovychChair of Non-Destructive Testing, TUM School of Engineering and Design, Technical University of Munich, Lichtenbergstr. 2, Garching, 85748, Germany.
Mohamed ElkarmotyDepartment of Mining, Petroleum, and Metallurgical Engineering, Faculty of Engineering, Cairo University, Gamaa Street 1, Giza, 12613, Egypt.
Mehdi TayoubiDassault Systèmes, 10 Rue Marcel Dassault, 78140, Vélizy-Villacoublay, France.
Hany HelalDepartment of Mining, Petroleum, and Metallurgical Engineering, Faculty of Engineering, Cairo University, Gamaa Street 1, Giza, 12613, Egypt.
Christian U GrosseChair of Non-Destructive Testing, TUM School of Engineering and Design, Technical University of Munich, Lichtenbergstr. 2, Garching, 85748, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study investigates the internal geometry of the granite block rows in the King's Chamber (KC) of the Great Pyramid of Giza using Non-destructive testing (NDT) with ultrasonic testing (UST) using shear wave echo arrays. As part of the ScanPyramids (SP) project measurement campaigns in 2022, the lower two block rows of all four walls were examined using ultrasonic shear-wave echo arrays (PD8000, Screening Eagle Technologies). The measurement strategy initially included rapid overview acquisitions using an 8-channel UST device to identify potential areas of interest. High-resolution, detailed measurements were then performed at these locations, particularly along the north wall (NW) and in the area of block labeled NW9, using a 16-channel configuration built from two UST devices. The data acquired during these campaigns were processed using a Fourier Transform Synthetic Aperture Focusing Technique (FT-SAFT) algorithm based on the general Synthetic Aperture Focusing Technique (SAFT), creating two-dimensional (2D) cross-sectional images that reveal internal reflectors. A reliable determination of reflector depth requires a precise measurement of the shear wave velocity, which was determined from measurements on the surfaces of 45 accessible granite blocks of the two lower block rows of the KC. The whole study was performed on these 45 blocks. The chamber-wide mean value of 3035 m/s ± 90 m/s results in a remaining depth uncertainty of only a few centimeters, arising from variations in stone properties and measurement uncertainties (up to ± 70 mm even for deep reflectors). Images reconstructed using an FT-SAFT enabled the determination of block thickness (i.e., the locations of backwalls), block joints, and the identification of additional internal reflectors at depths of up to approximately 3 m. The 16-channel UST device exhibited an improved signal-to-noise ratio (SNR) and greater penetration depth than the 8-channel UST device, enabling hyperbolic reflectors and anomalies behind individual blocks to be visualized more distinctly. From the reconstructed 2D images of the measurement profiles, a three-dimensional model of the lower two block rows was derived, providing for the first time a systematic view of the internal structure of the granite lining of the two lower block rows of the KC's walls. The results illustrate the potential of UST in combination with FT-SAFT for the NDT of massive historic stone structures, establishing a basis for subsequent multi-modal NDT analyses and structural evaluations of the Great Pyramid.

Indexed as

Great Pyramid of GizaKing’s Chamber (KC)Non-destructive testing (NDT)ScanPyramids (SP)Shear wave echo arraySynthetic Aperture Focusing Technique (SAFT)Ultrasonic testing (UST)

Identifiers

PMID42315545
PMCPMC13279776

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.