Evidence map›Paper›PMID 42312740›Full record

ArticleActa oncologica (Stockholm, Sweden)2026

Evaluation of 3D-CRT vs. VMAT for radiotherapy of whole breast with simultaneous integrated boost.

Gracinda Johansson, Rafat Kojoj, Sewa Surdashi, Martin Olin, Emil Fredén, Pelin Sen, Eija Dahl, Camilla Wendt

Abstract readEvaluation StudyComparative Study
In one paragraph

Article in Acta oncologica (Stockholm, Sweden), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Gracinda JohanssonMedical Physics, Diagnostics and Technology, Södersjukhuset, Stockholm, Sweden; Department och Clinical Science and Education, Karolinska Institutet, Stockholm, Sweden. gracinda.johansson@ki.se.ORCID 0000-0002-9904-7217
Rafat KojojMedical Physics, Diagnistics and Technology, Södersjukhuset, Stockholm, Sweden.ORCID 0009-0000-7689-0685
Sewa SurdashiMedical Physics, Diagnistics and Technology, Södersjukhuset, Stockholm, Sweden.ORCID 0009-0001-8281-8142
Martin OlinMedical Physics, Diagnistics and Technology, Södersjukhuset, Stockholm, Sweden.ORCID 0009-0000-8080-7012
Emil FredénMedical Physics, Diagnistics and Technology, Södersjukhuset, Stockholm, Sweden.ORCID 0000-0003-1788-9582
Pelin SenMedical Physics, Diagnistics and Technology, Södersjukhuset, Stockholm, Sweden.ORCID 0009-0006-6109-4874
Eija DahlDepartment of Oncology, Södersjukhuset, Stockholm, Sweden.
Camilla WendtDepartment of Oncology, Södersjukhuset, Stockholm, Sweden.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeThis study evaluates volumetric modulated arc therapy (VMAT) as a potential alternative to three-dimensional conformal radiotherapy (3D-CRT) for whole-breast radiotherapy (RT) with simultaneous-integrated boost (SIB). Patient/material and methods: Ten left-sided breast cancer patients previously treated in our institution (whole breast with SIB) were selected. Clinical plans were generated using tangential field-in-field 3D-CRT technique. VMAT plans were retrospectively created. Dosimetric evaluation was performed according to our clinical guidelines. A robustness evaluation of the 3D-CRT and VMAT plans against simulated anatomical and setup uncertainties was also performed. Differences between techniques were analysed using a two-sided Wilcoxon signed-rank test with a significance level of 0.05.

resultsBoth the 3D-CRT and VMAT plans fulfilled the clinical requirements for target volumes and organs at risk. VMAT plans showed a median increase in heart mean dose of 10.8%, compared to 3D-CRT (p < 0.05). Heart maximum dose was reduced by up to 56.7% with VMAT (p < 0.05), offering a clinically meaningful advantage. For the ipsilateral lung, no significant difference in mean dose was observed, V16Gy was significantly lower and V4Gy was significantly increased with VMAT. VMAT plans improved dose conformity to the boost planning target volume, (p < 0.05). Median monitor units (MU) values of 371 MU (359-466 MU) vs 927 MU (752-1018 MU) were obtained with 3D-CRT and VMAT. VMAT remained robust to simulated uncertainties for whole-breast but showed greater sensitivity in the boost volume.

interpretationVMAT was a feasible alternative to 3D-CRT for whole-breast RT with SIB, improving boost dose-conformity and reducing maximum heart dose. However, VMAT requires careful dosimetric evaluation and robustness assessment.

Indexed as

Breast NeoplasmsRadiotherapy, ConformalRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedUnilateral Breast NeoplasmsFemaleHeartHumansOrgans at RiskRadiotherapy DosageRetrospective Studies

Identifiers

PMID42312740
PMCPMC13285365

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.