ArticleRadiology advances2026
Standardizing attenuation across tube voltages and vertebral levels for opportunistic osteoporosis screening on low-dose chest CT.
Article in Radiology advances, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Opportunistic screening of osteoporosis on CT has emerged as a cost-effective strategy for bone health assessment. However, vertebral attenuation varies substantially with CT tube voltage and spinal level, limiting standardization. Purpose: To model and standardize vertebral attenuation across tube voltages and spinal levels on low-dose chest CT for opportunistic osteoporosis screening. Materials and Methods: This retrospective study included 589 patients (336 women; mean age ± standard deviation, 65.9 ± 12.4 years) who underwent 2 noncontrast low-dose chest CT examinations and 1 dual-energy X-ray absorptiometry within 3 months. Vertebral attenuation was measured at T10-L2 on CT using a deep learning-based software (AVIEW SpineBH, Coreline Soft). Osteoporosis was diagnosed using dual-energy X-ray absorptiometry. A linear mixed-effects model regressed attenuation on the logarithm of tube voltage, incorporating fixed effects for spinal level (T10-L2) and patient-specific random effects. Model performance was evaluated by converting the L1-120 kVp reference to other tube-voltage-level combinations and comparing predicted with observed attenuation using Pearson correlation, mean bias, and 95% limits of agreement. Diagnostic applicability was assessed by comparing receiver operating characteristic-derived thresholds with model-predicted thresholds converted from the reference. Results: Vertebral attenuation decreased by approximately 6-11 Hounsfield units (HU) for every 10-kVp increase (β = -88.8 HU per log[kVp]; Conclusions: A log-linear mixed-effects model enables population-level standardization of vertebral attenuation across tube voltages and spinal levels, supporting the development of more consistent opportunistic CT-based osteoporosis screening methods on noncontrast chest CT.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.