Evidence map›Paper›PMID 42311355›Full record

ArticleJournal of experimental orthopaedics2026

Clinical technique for augmented reality-guided tibial resection in kinematic alignment total knee arthroplasty: Real-time ligament elongation enables personalised soft tissue balance.

Atsushi Sato, Masataka Ota, Toshiharu Miyazawa, Misako Takizawa, Reo Nagasaka, Marika Mukunoki, Kanako Izukashi, Jun Oike, Takayuki Okumo, Saki Yagura and 2 more

Abstract read
In one paragraph

Article in Journal of experimental orthopaedics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Atsushi SatoShowa Medical University Fujigaoka Hospital, Orthopaedic Surgery Yokohama Japan.ORCID https://orcid.org/0000-0003-2197-9003
Masataka OtaShowa Medical University Fujigaoka Hospital, Orthopaedic Surgery Yokohama Japan.
Toshiharu MiyazawaShowa Medical University Fujigaoka Hospital, Orthopaedic Surgery Yokohama Japan.
Misako TakizawaShowa Medical University Fujigaoka Hospital, Orthopaedic Surgery Yokohama Japan.
Reo NagasakaShowa Medical University Koto Toyosu Hospital, Orthopaedic Surgery Tokyo Japan.
Marika MukunokiShowa Medical University Fujigaoka Hospital, Orthopaedic Surgery Yokohama Japan.
Kanako IzukashiShowa Medical University Fujigaoka Hospital, Orthopaedic Surgery Yokohama Japan.
Jun OikeShowa Medical University Koto Toyosu Hospital, Orthopaedic Surgery Tokyo Japan.
Takayuki OkumoShowa Medical University School of Medicine, Physiology Tokyo Japan.
Saki YaguraShowa Medical University Fujigaoka Hospital, Orthopaedic Surgery Yokohama Japan.
Takayuki KoyaShowa Medical University Koto Toyosu Hospital, Orthopaedic Surgery Tokyo Japan.
Koji KanzakiShowa Medical University Fujigaoka Hospital, Orthopaedic Surgery Yokohama Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Kinematic alignment (KA) total knee arthroplasty (TKA) aims to restore native knee kinematics by aligning prosthetic components with each patient's constitutional anatomy. While femoral resurfacing is well established, tibial resection in KA-TKA remains largely subjective, particularly in cases with advanced deformity or bone loss. This study introduces a novel augmented reality (AR)-based technique for tibial resection that utilises real-time ligament elongation patterns to support personalised alignment. Methods: More than 200 consecutive KA-TKA procedures were performed using an AR navigation system (NextAR, Medacta) with medial-stabilised implants (GMK Sphere). After femoral resurfacing and osteophyte removal, trial femoral components were inserted to restore functional intraoperative reference configuration, thereby defining a 'zero-position' baseline. Real-time elongation data of the medial and lateral collateral ligaments were visualised throughout the full range of motion via AR smart glasses. Tibial resection parameters-including varus/valgus angle and posterior slope-were quantitatively adjusted according to elongation patterns to replicate physiological soft-tissue tension. Spacer blocks were used intraoperatively to verify bone-gap balance. Results: Intraoperative tibial adjustments guided by ligament elongation patterns enabled patient-specific resection strategies without reliance on ambiguous osseous landmarks or purely subjective gap assessments. This approach facilitated consistent intraoperative evaluation of medial and lateral soft-tissue behaviour in both extension and flexion. Conclusion: This AR-based KA-TKA technique enables individualised tibial resection guided by real-time ligament behaviour. It provides a reproducible and objective framework to support soft-tissue-informed intraoperative decision-making, particularly in patients with complex deformities. This approach may complement existing KA principles and serve as a foundation for future outcome-based investigations. Level of Evidence: NA.

Indexed as

augmented reality navigationkinematic alignmentligament elongation patternsoft‐tissue balancetotal knee arthroplasty

Identifiers

PMID42311355
PMCPMC13270349

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.