Compact dual-channel visible-light fluorescence endoscope for real-time molecular imaging: system design and validation in ectopic pregnancy tissue.
Article in Biomedical optics express, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Intraoperative identification of early ectopic pregnancy tissue remains challenging because chorionic villi often exhibit low visual contrast from surrounding inflamed or hemorrhagic tissue under conventional white-light endoscopy. To address this limitation, we developed a compact dual-channel visible-light fluorescence endoscopic imaging system configured as a modular 10 mm rigid endoscopic platform compatible with standard 10 mm laparoscopic workflows for real-time dual-channel acquisition and fusion. The system integrates a narrow-band 490 nm LED excitation source with a customized long-pass dichroic beam-splitting module to simultaneously acquire targeted fluorescence at ∼515 nm and diffuse reflectance at 490 nm. The two image streams are synchronized and fused to provide real-time molecular-anatomical visualization. Using a FITC-labeled anti-