Evidence map›Paper›PMID 42311292›Full record

ArticleBiomedical optics express2026

Application of gradient-consensus Richardson-Lucy deconvolution to noisy undersampled brightfield microscopy data.

Yiming Liu, Sjoerd Stallinga

Abstract read
In one paragraph

Article in Biomedical optics express, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Yiming LiuDepartment of Imaging Physics, Delft University of Technology, Delft, The Netherlands.ORCID https://orcid.org/0009-0006-9836-0662
Sjoerd StallingaDepartment of Imaging Physics, Delft University of Technology, Delft, The Netherlands.ORCID https://orcid.org/0000-0003-4978-3272

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The gradient-consensus Richardson-Lucy (GC-RL) deconvolution algorithm is a novel approach to contrast restoration in high-resolution microscopy imaging without excessive noise amplification. We evaluate this method in this work, focusing on the impact of the noise level of the input image, of imperfections and deviations in image formation from the ideal incoherent case, and of using undersampled input data. The gain in spectral signal to noise ratio (SSNR) is larger when the noise level of the raw image is lower. We also find a positive impact on SSNR gain from using an optical transfer function (OTF) in the deconvolution that has a decreased spatial frequency response compared to the ideal incoherent OTF. A simple upsampling scheme, embedded in the GC-RL deconvolution, is demonstrated to be suitable for undersampled data. We show our results on simulated data, on fluorescence microscopy data, and on brightfield microscopy data of a breast tumour section. The GC-RL method has potential for whole slide imaging technology to retrieve diagnostically relevant image features at the smallest length scales from scanned images at lower resolution, providing a gain in throughput and data storage requirements.

Identifiers

PMID42311292
PMCPMC13271214

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.