Evidence map›Paper›PMID 42311291›Full record

ArticleBiomedical optics express2026

Fiber-optic fluorescence reader for multiplex point-of-care monitoring.

Vladislav Reimer, Georgios Ctistis, Katarina Fedorov, Philip Guehlke, Christian Waltermann, Hasan Al-Bar, Dimitrios Theodoridis, Pascal Schröder, Hainer Wackerbarth, Thorsten Perl and 6 more

Abstract read
In one paragraph

Article in Biomedical optics express, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

16 authors.

Vladislav ReimerFiSens GmbH, Salzdahlumer Str. 196, 38126 Braunschweig, Germany.
Georgios CtistisInstitut für Nanophotonik Göttingen, Department of Photonic Sensor Technologies, Hans-Adolf-Krebs-Weg 1, 37077 Göttingen, Germany.ORCID https://orcid.org/0000-0003-3177-698X
Katarina Fedorovnal von minden GmbH, Robert-Bosch-Breite 23, 37079, Göttingen, Germany.
Philip GuehlkeFiSens GmbH, Salzdahlumer Str. 196, 38126 Braunschweig, Germany.
Christian WaltermannFiSens GmbH, Salzdahlumer Str. 196, 38126 Braunschweig, Germany.
Hasan Al-BarFiSens GmbH, Salzdahlumer Str. 196, 38126 Braunschweig, Germany.
Dimitrios Theodoridisnal von minden GmbH, Robert-Bosch-Breite 23, 37079, Göttingen, Germany.
Pascal SchröderInstitut für Nanophotonik Göttingen, Department of Photonic Sensor Technologies, Hans-Adolf-Krebs-Weg 1, 37077 Göttingen, Germany.
Hainer WackerbarthInstitut für Nanophotonik Göttingen, Department of Photonic Sensor Technologies, Hans-Adolf-Krebs-Weg 1, 37077 Göttingen, Germany.
Thorsten PerlDepartment of General, Visceral and Pediatric Surgery, University Medical Center Goettingen, Robert-Koch-Str. 40, 37075 Goettingen, Germany.
Isabell EickelDepartment of General, Visceral and Pediatric Surgery, University Medical Center Goettingen, Robert-Koch-Str. 40, 37075 Goettingen, Germany.
Maja Wagemann-SüssDepartment of General, Visceral and Pediatric Surgery, University Medical Center Goettingen, Robert-Koch-Str. 40, 37075 Goettingen, Germany.
Frank StreitDepartment Department of Clinical Chemistry, University Medical Center Göttingen, Göttingen, Robert-Koch-Str. 40, 37075, Germany.
Wolfgang SchippersFiSens GmbH, Salzdahlumer Str. 196, 38126 Braunschweig, Germany.
Alexander MehrenFiSens GmbH, Salzdahlumer Str. 196, 38126 Braunschweig, Germany.
Jan KochFiSens GmbH, Salzdahlumer Str. 196, 38126 Braunschweig, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We present a compact fiber-optic fluorescence reader for quantitative, multiplex point-of-care (PoC) analysis of lateral flow assays (LFAs). The system uses a dual-port fiber Bragg grating (FBG) spectrometer for spectral discrimination and interchangeable excitation sources covering 400-800 nm to support multiple fluorophores. As a proof of principle, we quantified piperacillin in human serum with an europium nanoparticle-based competitive LFA, achieving a limit of detection (LOD) of 12.9 mg/L and a dynamic range of 10-500 mg/L. The reader-LFA system showed strong agreement with a laboratory reference method (Pearson's r = 0.95) and a mean absolute error of 22.9 mg/L across ten patient samples. In addition, we demonstrate multiplex detection of opiate and cocaine markers using distinct fluorophores on a single test line. These results support the feasibility of portable, spectrally resolved PoC diagnostics for therapeutic drug monitoring and multiplex biomarker detection in clinical and low-resource settings.

Identifiers

PMID42311291
PMCPMC13271212

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.