Evidence map›Paper›PMID 42310654›Full record

ArticleBMC oral health2026

Posterior implant angulation without cantilever reduction in mandibular All-on-4: a controlled finite element analysis of stress transfer and implant macrodesign effects.

Sercan Küçükkurt

Abstract read
In one paragraph

Article in BMC oral health, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Sercan KüçükkurtDepartment of Oral and Maxillofacial Surgery, Faculty of Dentistry, Istanbul Aydın University, Beşyol Mahallesi, Akasya Sokak No: 6 Küçükçekmece, Istanbul, Türkiye. sercankucukkurt@aydin.edu.tr.ORCID 0000-0002-4095-957X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPosterior implant angulation is widely used in mandibular All-on-4 rehabilitation, but its proposed biomechanical benefit is often confounded by concurrent cantilever reduction and/or increased distal support. This finite element analysis isolated the effect of posterior angulation under standardized prosthetic geometry and assessed whether implant macrodesign modified stress transfer under healed, bonded-interface assumptions.

methodsFour three-dimensional finite element models of an edentulous mandible were created: axial posterior implants (VERT4) and 30° distally tilted posterior implants (ALL4). Each configuration was simulated with two implant macrodesigns (NobelActive and Straumann BL). A 12-unit screw-retained prosthesis extending to the first molars was modeled with identical emergence profile, distal extension, and cantilever length across all models, without angulation-dependent distal implant-length gain. A healed condition was simulated using bonded bone-implant interfaces, and linear static analyses were performed. Two unilateral vertical load cases (300 N) were applied via a rigid food bolus over the left canine or left first-molar region. Principal stresses were extracted for cortical and trabecular bone, and von Mises stresses for implants, multiunit abutments, and the framework and veneering complex. Ranking stability was tested by ± 10% load variation.

resultsWhen posterior angulation was applied without cantilever reduction or increased distal support, tilted models showed higher peak stresses than axial models. Under first-molar loading, ALL4-N produced the highest cortical stresses (Pmax 100.44 MPa; Pmin - 95.30 MPa) and posterior implant von Mises stress (925.82 MPa). Under canine loading, ALL4-N also showed the highest posterior implant stress (546.94 MPa). The highest anterior multiunit abutment stress occurred in ALL4-S under first-molar loading (287.27 MPa). Across matched configurations, NobelActive models showed higher implant and connection stresses than Straumann BL models. Relative rankings were unchanged in sensitivity analyses.

conclusionsWithin this linear-elastic, healed-interface model, posterior implant angulation did not provide a biomechanical advantage when used without cantilever reduction or increased distal support. It was associated with increased mechanical demand in peri-implant bone and implant-prosthetic components under unilateral loading. Findings should be interpreted as comparative trends within this model, not direct predictions of clinical failure or generalized inferiority of tilted implants in other scenarios. Implant macrodesign also influenced stress transfer.

Indexed as

Dental Implantation, EndosseousDental ImplantsDental Stress AnalysisFinite Element AnalysisMandibleBiomechanical PhenomenaDental Prosthesis DesignDental Prosthesis, Implant-SupportedHumansImaging, Three-DimensionalJaw, EdentulousStress, MechanicalDental ImplantsAll-on-4Finite element analysisImplant angulationImplant macrodesignMandibleMultiunit abutment

Identifiers

PMID42310654
PMCPMC13520164

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.