Evidence map›Paper›PMID 42310605›Full record

ArticleBMC ophthalmology2026

Factors leading to high intraocular pressure in Intraocular Device-Associated Uveitis (IDAU): a retrospective nested case-control study from a tertiary uveitis cohort.

Jakkrit Juhong, Thanapong Somkijrungroj, Wijak Kongwattananon, Somtaporn Ueathaweephol, Krit Pongpirul

Abstract read
In one paragraph

Article in BMC ophthalmology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jakkrit JuhongDepartment of Ophthalmology, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, 1873 Rama 4 road, Pathum wan, Bangkok, 10330, Thailand.
Thanapong SomkijrungrojDepartment of Ophthalmology, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, 1873 Rama 4 road, Pathum wan, Bangkok, 10330, Thailand. thanapongmd@gmail.com.
Wijak KongwattananonDepartment of Ophthalmology, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, 1873 Rama 4 road, Pathum wan, Bangkok, 10330, Thailand.
Somtaporn UeathaweepholDepartment of Ophthalmology, Faculty of Medicine, Burachat Chaiyakorn Hospital, Bangkok, Thailand.
Krit PongpirulDepartment of Preventive and Social Medicine, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIntraocular device-associated uveitis (IDAU) - which we propose as a more precise alternative to the traditional term "uveitis-glaucoma-hyphema (UGH) syndrome" - is a rare but potentially sight-threatening complication of intraocular device implantation. Elevated intraocular pressure (IOP) is a major driver of visual morbidity in IDAU, but the risk factors that predispose affected patients to IOP elevation remain poorly characterised. We aimed to describe the clinical spectrum of IDAU and to identify independent risk factors for elevated IOP in this population, using the Chulalongkorn University Uveitis Cohort (CU

methodsThis first nested case-control study within the Chulalongkorn University Uveitis Cohort (CU²C) enrolled 375 subjects followed at a tertiary uveitis clinic in Thailand over 8 years (August 2014-June 2022). Cases (n = 30) were IDAU patients with elevated IOP (> 21 mmHg); controls (n = 60) were IDAU patients with normal IOP, sampled at a 1:2 ratio from the same cohort. Univariate and multivariate logistic regression were used to calculate odds ratios (OR) and 95% confidence intervals (CI) for candidate risk factors.

resultsWe retrospectively identified 90 subjects who developed IDAU. Following a one-to-two case-control ratio, 30 case subjects and 60 control subjects were included. Three factors were significantly associated with high intraocular pressure in IDAU. These included intraocular lens (IOL) malposition (AOR: 8.30, 95% CI 1.25 to 54.76), long eye (AOR: 8.08, 95% CI 1.18 to 55.16) and age (AOR: 1.18, 95% CI 1.07 to 1.31). There was no statistical evidence of effects of hypertension, ruptured posterior capsule, vitrectomized eye, transillumination iris defect (TID), pseudophacodonesis and single-piece IOL in sulcus on high IOP in IDAU.

conclusionIn this first nested case-control study of IDAU, IOL malposition, long axial length (> 25 mm), and older age were independently associated with elevated IOP. These findings should inform clinician awareness and post-operative monitoring strategies for high-risk IDAU patients.

Indexed as

Intraocular PressureOcular HypertensionUveitisAdultAgedCase-Control StudiesFemaleHumansMaleMiddle AgedRetrospective StudiesRisk FactorsCohort studyIDAUIntraocular device-associated uveitisIntraocular lens malpositionIntraocular pressureNested case-control studyRisk factorsUveitis-glaucoma-hyphema syndrome

Identifiers

PMID42310605
PMCPMC13520342

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked