Evidence map›Paper›PMID 42307400›Full record

ArticleArquivos brasileiros de cirurgia digestiva : ABCD = Brazilian archives of digestive surgery2026

Robotic surgery for median arcuate ligament syndrome: technical aspects and imaging correlation.

Michele Andreza Fidelis Siqueira, Rafael Hardman Daim, Maria Eduarda Hardman Knaesel, Ricardo Lemos Cotta-Pereira

Abstract readCase Reports
In one paragraph

Article in Arquivos brasileiros de cirurgia digestiva : ABCD = Brazilian archives of digestive surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Michele Andreza Fidelis SiqueiraInstituto D'Or de Pesquisa e Ensino, Medical Residency Program in Digestive Surgery - Rio de Janeiro (RJ), Brazil.ORCID http://orcid.org/0000-0001-7697-0220
Rafael Hardman DaimInstituto Técnico Educacional Souza Marques, Medical School - Rio de Janeiro (RJ), Brazil.ORCID http://orcid.org/0009-0004-4548-6259
Maria Eduarda Hardman KnaeselInstituto Técnico Educacional Souza Marques, Medical School - Rio de Janeiro (RJ), Brazil.ORCID http://orcid.org/0009-0003-4700-2687
Ricardo Lemos Cotta-PereiraInstituto D'Or de Pesquisa e Ensino, Medical Residency Program in Digestive Surgery - Rio de Janeiro (RJ), Brazil.ORCID http://orcid.org/0009-0006-0755-0883

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMedian arcuate ligament syndrome (MALS) is an uncommon condition characterized by chronic and intermittent abdominal pain, typically postprandial, and weight loss, caused by extrinsic compression of the celiac trunk by the median arcuate ligament. The pathophysiology of the disease is not fully understood. Diagnosis is challenging due to nonspecific symptoms, and requires a careful correlation between clinical findings and imaging studies.

aimsTo demonstrate the feasibility, safety, and technical aspects of robotic median arcuate ligament release using a case-based approach with detailed imaging correlation.

methodsThe authors report the technical aspects in an elderly male patient with typical symptoms of MALS, who underwent robotic-assisted median arcuate ligament release using the da Vinci X platform. Preoperative evaluation included CT angiography and color Doppler ultrasound, demonstrating focal proximal celiac trunk stenosis.

resultsThe robotic approach allowed precise dissection and complete decompression of the celiac trunk without intraoperative complications. Postoperative imaging demonstrated resolution of the stenosis and normalization of Doppler flow parameters. The patient experienced complete symptom resolution, and remained asymptomatic after one year of follow-up.

conclusionsRobotic median arcuate ligament release is a safe and effective minimally invasive option, providing excellent visualization and precise dissection in a challenging anatomical region. This technique should be considered a valuable approach for selected patients with MALS. CENTRAL MESSAGE: Robotic surgery, due to the surgeon's ergonomics and the stability of the arms and instruments, wrist movement, and magnified threedimensional vision, allows for facilitated and safe access to the origin of the celiac artery as well as the dissection of fibrous tissues, innervation, and lymphatic vessels surrounding it. Given this, robotic surgery becomes feasible, effective, and safe for treating this syndrome, and it should be considered a preferred option in selected patients. PERSPECTIVES: The median arcuate ligament syndrome should be considered in cases of abdominal pain with no defined causes. A high index of suspicion can diagnose and treat more cases. Moreover, it is expected that robotic surgery will become increasingly accessible, allowing for an expansion of its indications.

Indexed as

Median Arcuate Ligament SyndromeRobotic Surgical ProceduresAgedCeliac ArteryHumansMale