ArticleBone & joint research2026
Subluxation-induced liner adhesion and the effect of impaction to prevent liner dislocation in ceramic hip arthroplasty.
Article in Bone & joint research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Aims: Ceramic-on-ceramic bearings are commonly used in total hip arthroplasty. The long-term clinical results show low revision rates. However, there might be the possibility of liner dislocation during clinical use, due to adhesion forces occurring in the bearing. Methods: In this study, the adhesion forces during subluxation of the ceramic head from the liner were measured. Two different implant systems (Mathys SeleXys and DePuy Synthes Pinnacle) with two different head sizes (28 mm and 36 mm) were studied. Additionally, the liner-to-cup fixation forces with three different liner sizes (44 mm, 52 mm, and 64 mm) were analyzed to correlate the adhesion forces with the liner fixation force. Three different assembly forces (1 kN, 2 kN, and 4 kN) were considered. Results: There was a significant difference in the adhesion forces between Mathys SeleXys and Depuy Synthes Pinnacle bearings at a head size of 28 mm. However, no significant difference was found for the 36 mm head size. The maximum adhesion force reached 265 N. The liner fixation forces varied depending on the assembly force. For an assembly force of 1 kN, the fixation forces varied between 95 and 385 N, which is partly below the corresponding adhesion force. For assembly forces of 2 kN or more, the liner fixation force was always above the adhesion forces. Conclusion: A low liner impaction force can lead to liner dislocation due to possible adhesion forces between the ceramic head and the ceramic liner. Sufficient liner impaction forces of more than 2 kN should be applied to prevent the risk of adhesion-related liner extractions.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.