Evidence map›Paper›PMID 42306767›Full record

ArticleJournal of thoracic disease2026

Minimally invasive off-pump coronary artery bypass grafting is associated with reduced postoperative intra-aortic balloon pump use.

Yanbin Lei, Guang Li, Jiazhen Mei, Yi Xu, Zhao Yang, Zheng Qu, Yuming Hao, Bin You

Abstract read
In one paragraph

Article in Journal of thoracic disease, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yanbin Lei *Department of Cardiovascular Surgery, Minimally Invasive Cardiac Surgery Center, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Guang Li *Department of Cardiovascular Surgery, Minimally Invasive Cardiac Surgery Center, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Jiazhen Mei *Department of Cardiovascular Surgery, Minimally Invasive Cardiac Surgery Center, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Yi XuDepartment of Cardiovascular Surgery, Minimally Invasive Cardiac Surgery Center, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Zhao YangDepartment of Cardiovascular Surgery, Minimally Invasive Cardiac Surgery Center, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Zheng QuDepartment of Cardiovascular Surgery, Minimally Invasive Cardiac Surgery Center, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Yuming HaoDepartment of Cardiovascular Surgery, Minimally Invasive Cardiac Surgery Center, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Bin YouDepartment of Cardiovascular Surgery, Minimally Invasive Cardiac Surgery Center, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Minimally invasive cardiac surgery-coronary artery bypass grafting (MICS-CABG) is increasingly adopted; however, its association with postoperative intra-aortic balloon pump (IABP) use-a marker of refractory low cardiac output-has not been well characterized in large patient cohorts. This study aimed to evaluate whether MICS-CABG was independently associated with reduced postoperative IABP use compared with conventional sternotomy CABG. Methods: We retrospectively analyzed 2,084 patients who underwent CABG between 2017 and 2024 at a single high-volume center (sternotomy: n=1,458; MICS-CABG: n=626). All procedures were primarily off-pump. The primary outcome was postoperative IABP use. Multivariable logistic regression was used to identify independent predictors, and propensity score matching (PSM) was performed to control for baseline differences. Mediation analysis assessed whether operative time or transfusion volume explained the observed association. Results: Postoperative IABP use was significantly lower after MICS-CABG than after sternotomy, both in the overall cohort (1.8% Conclusions: In a center using a standardized rescue-IABP protocol, MICS-CABG was associated with significantly lower postoperative IABP utilization compared with conventional sternotomy CABG. This association was partly mediated by shorter operative time, suggesting that procedural efficiency may contribute to improved perioperative hemodynamic stability. However, these findings should be interpreted in the context of potential residual confounding, including differences in patient selection, sex distribution, and revascularization complexity reflected by the number of grafts.

Indexed as

circulatory supportcoronary artery bypass grafting (CABG)Coronary artery disease (CAD)intra-aortic balloon pump (IABP)minimally invasive cardiac surgery (MICS)

Identifiers

PMID42306767
PMCPMC13266661

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.